D
Prm_Text_Ref = 20
EndExtUserPrmData
ExtUserPrmData = 39 "Diagnostics Format"
BitArea(2-3) 0 0-2
Prm_Text_Ref = 21
EndExtUserPrmData
ExtUserPrmData = 40 "Error Behaviour"
BitArea(2-3) 1 1-3
Prm_Text_Ref = 22
EndExtUserPrmData
ExtUserPrmData = 41 "Error Behaviour packed Module 1"
BitArea(2-3) 1 1-3
Prm_Text_Ref = 22
EndExtUserPrmData
ExtUserPrmData = 42 "Error Behaviour packed Module 2"
BitArea(2-3) 1 1-3
Prm_Text_Ref = 22
EndExtUserPrmData
ExtUserPrmData = 43 "Error Behaviour packed Module 3"
BitArea(2-3) 1 1-3
Prm_Text_Ref = 22
EndExtUserPrmData
ExtUserPrmData = 44 "Error Behaviour packed Module 4"
BitArea(2-3) 1 1-3
Prm_Text_Ref = 22
EndExtUserPrmData
ExtUserPrmData = 45 "Replacement Value Channel 1"
Signed16 0 -32768-32767
EndExtUserPrmData
ExtUserPrmData = 46 "Replacement Value Channel 2"
Signed16 0 -32768-32767
EndExtUserPrmData
ExtUserPrmData = 47 "Replacement Value Byte 0 Bit 0"
Bit(0) 0 0-1
Prm_Text_Ref = 23
EndExtUserPrmData
ExtUserPrmData = 48 "Replacement Value Byte 0 Bit 1"
Bit(1) 0 0-1
Prm_Text_Ref = 23
EndExtUserPrmData
ExtUserPrmData = 49 "Replacement Value Byte 0 Bit 2"
Bit(2) 0 0-1
Prm_Text_Ref = 23
EndExtUserPrmData
ExtUserPrmData = 50 "Replacement Value Byte 0 Bit 3"
Bit(3) 0 0-1
Prm_Text_Ref = 23
EndExtUserPrmData
ExtUserPrmData = 51 "Replacement Value Byte 0 Bit 4"
Bit(4) 0 0-1
Prm_Text_Ref = 23
EndExtUserPrmData
ExtUserPrmData = 52 "Replacement Value Byte 0 Bit 5"
Bit(5) 0 0-1
Prm_Text_Ref = 23
EndExtUserPrmData
ExtUserPrmData = 53 "Replacement Value Byte 0 Bit 6"
Bit(6) 0 0-1
Prm_Text_Ref = 23
EndExtUserPrmData
ExtUserPrmData = 54 "Replacement Value Byte 0 Bit 7"
Bit(7) 0 0-1
Prm_Text_Ref = 23
EndExtUserPrmData
ExtUserPrmData = 55 "Replacement Value Byte 1 Bit 0"
Bit(0) 0 0-1
Prm_Text_Ref = 23
EndExtUserPrmData
ExtUserPrmData = 56 "Replacement Value Byte 1 Bit 1"
Bit(1) 0 0-1
Prm_Text_Ref = 23
EndExtUserPrmData
ExtUserPrmData = 57 "Replacement Value Byte 1 Bit 2"
Bit(2) 0 0-1
Prm_Text_Ref = 23
EndExtUserPrmData
ExtUserPrmData = 58 "Replacement Value Byte 1 Bit 3"
Bit(3) 0 0-1
Summary of Contents for VersaPoint IC220PBI002
Page 4: ......
Page 10: ...Contents x VersaPoint I O System Profibus DP NIU User s Manual August 2005 GFK 1911B...
Page 80: ...5 14 VersaPoint I O System Profibus DP NIU User s Manual August 2005 GFK 1911B 5...
Page 100: ...6 20 VersaPoint I O System Profibus DP NIU User s Manual August 2005 GFK 1911B 6...
Page 166: ...A 10 VersaPoint I O System Profibus DP NIU User s Manual August 2005 GFK 1911B A...