Configuring Meter Data
4-5
March 2004
Entering RS232
Communication
Settings
With the
Communication
submenu, you can set the parameters by
which the UTX878 communicates to a PC or terminal over the RS232
interface. You can set the Node ID as well as the baud rate, parity,
stop bits and data bits. To access the
Communication
submenu:
1.
Press [ESC]. The UTX878 enters the
User Program.
2.
Press the [
X
] key until
CONFIG
is bracketed and press [ENT].
3.
Press the [
T
] key until
Communication
is highlighted. Then press
[ENT].
4.
The next window offers a selection between Node ID and RS232.
Use the [
S
] and [
T
] keys to scroll to the desired option and press
[ENT].
•
If you select Node ID:
The meter asks for a specific ID number. Use the arrow keys to
enter the desired number (from 1 to over 255) and press [ENT].
•
If you select RS232, a list of six options appears. Scroll to the
desired option and press [ENT].
a.
The first option asks for the RS232
Status
. Scroll to the desired
selection (ON or OFF), and press [ENT]. (If you are not using
RS232, selecting OFF increases response time at lower power
settings.)
b.
The next option asks for the
Baud Rate
. The available choices
extend from 300 to 115,200 baud. Scroll to the desired
selection and press [ENT].
c.
The next option is
Parity
. Scroll to the desired selection (none,
even, or odd) and press [ENT].
d.
The next prompt asks you to select one or two
Stop Bits
. Scroll
to the desired selection and press [ENT].
e.
The next option asks you to select either seven or eight
Data
Bits
. Scroll to the desired selection and press [ENT].
f.
The final option asks for the interface type.Scroll to
HyperTer
(for Hyperterminal) and press [ENT].
Press [ESC] twice to return to the
CONFIG
menu, or continue
pressing [ESC] until the display screen reappears.
Summary of Contents for UTX878 Ultrasonic
Page 2: ...iii March 2004 The UTX878 Flow Transmitter and Transducers ...
Page 8: ...Chapter 1 ...
Page 20: ...March 2004 Installation 1 11 Figure 1 5 UTX878 Outline and Installation Dwg 712 1196 rev 2 ...
Page 22: ...March 2004 Installation 1 13 Figure 1 7 UTX878 Wiring Diagram Dwg 702 528 rev 2 ...
Page 23: ...Chapter 2 ...
Page 45: ...Chapter 3 ...
Page 52: ...Chapter 4 ...
Page 60: ...Chapter 5 ...
Page 65: ...Chapter 6 ...
Page 75: ...Chapter 7 ...
Page 80: ...Appendix A ...
Page 85: ...Appendix B ...
Page 86: ...CE Mark Compliance Introduction B 1 EMC Compliance B 1 ...
Page 88: ...Appendix C ...
Page 89: ...Data Records Site Data C 1 ...
Page 93: ...Appendix D ...
Page 94: ...Service Record Introduction D 1 Data Entry D 1 Diagnostic Parameters D 3 ...