Installing the Dampening Material, Transducers and Fixtures
3-8
April 2009
18 (450)
<0.38 (9.7)
0.2
300 (21.7)
78 (23.8)
59 (18.0)
47 (14.3)
<0.50 (12.7)
0.2
800 (56.2)
20 (500)
<0.38 (9.7)
0.2
300 (21.7)
70 (21.3)
52 (15.9)
42 (12.8)
<0.50 (12.7)
0.2
800 (56.2)
24 (600)
<0.38 (9.7)
0.2
300 (21.7)
56 (17.1)
42 (12.8)
34 (10.4)
<0.50 (12.7)
0.2
800 (56.2)
Table 3-2: PT878GC Installation Requirements for Natural Gas (Continued)
Pipe Size ANSI
(DIN)
Pipe Wall Inches
(mm)
Transducer
MHz
Min. Pressure
psig (bar)
Maximum Velocity, ft/s (m/s)
Single Traverse
Dual Traverse
Triple Traverse
Four Traverse