B-22
T35 Transformer Protection System
GE Multilin
B.4 MEMORY MAPPING
APPENDIX B
B
3A34
...Repeated for Field Contact Input 29
3A3F
...Repeated for Field Contact Input 30
3A4A
...Repeated for Field Contact Input 31
3A55
...Repeated for Field Contact Input 32
3A60
...Repeated for Field Contact Input 33
3A6B
...Repeated for Field Contact Input 34
3A76
...Repeated for Field Contact Input 35
3A81
...Repeated for Field Contact Input 36
3A8C
...Repeated for Field Contact Input 37
3A97
...Repeated for Field Contact Input 38
3AA2
...Repeated for Field Contact Input 39
3AAD
...Repeated for Field Contact Input 40
Field Unit Shared Inputs (Read/Write Setting) (16 modules)
3B00
Field Shared Input 1 ID
0 to 65535
---
1
F205
"SI 1"
3B06
Field Shared Input 1 Unit Origin 1
0 to 8
---
1
F256
0 (None)
3B07
Field Shared Input 1 Channel Origin 1
1 to 15
---
1
F001
1
3B08
Field Shared Input 1 Events
0 to 1
---
1
F102
1 (Enabled)
3B09
...Repeated for Field Shared Input 2
3B12
...Repeated for Field Shared Input 3
3B1B
...Repeated for Field Shared Input 4
3B24
...Repeated for Field Shared Input 5
3B2D
...Repeated for Field Shared Input 6
3B36
...Repeated for Field Shared Input 7
3B3F
...Repeated for Field Shared Input 8
3B48
...Repeated for Field Shared Input 9
3B51
...Repeated for Field Shared Input 10
3B5A
...Repeated for Field Shared Input 11
3B63
...Repeated for Field Shared Input 12
3B6C
...Repeated for Field Shared Input 13
3B75
...Repeated for Field Shared Input 14
3B7E
...Repeated for Field Shared Input 15
3B87
...Repeated for Field Shared Input 16
Field Unit Contact Outputs (Read/Write Setting) (8 modules)
3B90
Field Contact Output 1 ID (6 items)
---
---
---
F205
"FCO U /OUT"
3BB4
Field Output 1 Operate (6 items)
0 to 4294967295
---
1
F300
0
3BC0
Field Output 1 Seal In (6 items)
0 to 4294967295
---
1
F300
0
3BCC
Field Output 1 Events (6 items)
0 to 1
---
1
F102
1 (Enabled)
3BD2
...Repeated for Field Contact Output 2
3C14
...Repeated for Field Contact Output 3
3C56
...Repeated for Field Contact Output 4
3C98
...Repeated for Field Contact Output 5
3CDA
...Repeated for Field Contact Output 6
3D1C
...Repeated for Field Contact Output 7
3D5E
...Repeated for Field Contact Output 8
Field Unit Latching Outputs (Read/Write Setting) (8 modules)
3DC7
Field Latching Output 1 ID
0 to 1
---
1
F205
"FLO Ux /LO"
3DCD
Field Latching Output 1 Open
0 to 4294967295
---
1
F300
0
3DCF
Field Latching Output 1 Close
0 to 4294967295
---
1
F300
0
3DD1
Field Latching Output 1 Events
0 to 1
---
1
F102
1 (Enabled)
3DD2
Field Latching Output 1 Reserved (2 items)
0 to 1
---
1
F001
0
3DD4
...Repeated for Field Latching Output 2
3DE1
...Repeated for Field Latching Output 3
3DEE
...Repeated for Field Latching Output 4
3DFB
...Repeated for Field Latching Output 5
Table B–10: MODBUS MEMORY MAP (Sheet 14 of 52)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Summary of Contents for T35 UR Series
Page 10: ...x T35 Transformer Protection System GE Multilin TABLE OF CONTENTS ...
Page 48: ...2 18 T35 Transformer Protection System GE Multilin 2 2 SPECIFICATIONS 2 PRODUCT DESCRIPTION 2 ...
Page 314: ...5 192 T35 Transformer Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 338: ...6 24 T35 Transformer Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Page 350: ...7 12 T35 Transformer Protection System GE Multilin 7 2 TARGETS 7 COMMANDS AND TARGETS 7 ...
Page 366: ...8 16 T35 Transformer Protection System GE Multilin 8 2 CYBERSENTRY 8 SECURITY 8 ...
Page 406: ...A 14 T35 Transformer Protection System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Page 540: ...D 10 T35 Transformer Protection System GE Multilin D 1 IEC 60870 5 104 PROTOCOL APPENDIX D D ...
Page 552: ...E 12 T35 Transformer Protection System GE Multilin E 2 DNP POINT LISTS APPENDIX E E ...
Page 560: ...F 8 T35 Transformer Protection System GE Multilin F 3 WARRANTY APPENDIX F F ...