Page 5
Fail to Communicate
The NX-6 will illuminate the "Service" LED if a report fails to reach the central station. If enabled, when the next report
is successfully communicated, a “Fail to Communicate” code will be reported.
(Loc. 37, pg. 19)
Fire Alarm Verification
When enabled, the NX-6 will verify a Fire alarm by requiring more than one trip on a smoke detector within a specified
time before creating an alarm.
(Loc. 40, pg. 20)
This feature is not approved for residential use in California.
Force Arming
NOTE: This feature must be disabled for UL installations
When enabled, the NX-6 can be Force Armed with zones violated. Under this condition, if a force armable zone is not
secure, the "Ready" LED will flash. At the end of the exit delay, these zones will become bypassed. If these zones
become secured any time during the arming cycle, they will be unbypassed and active in the system. If "Bypass
Report" is enabled, the force arming zones can be programmed to report bypass when they are Force Armed (default),
or to not report bypass even if "Bypass Report" is enabled.
(Loc. 37, and 111-149, pg. 19 & 28)
Group Bypass
NOTE: This feature must be disabled for UL installations
A designated group of zones can be programmed to bypass by pressing [
Bypass
]- [
0
]-[
Bypass
]- [
Bypass
] prior to
arming.
(Loc. 111-149, pg. 28)
Immediate Restore By Zone
The NX-6 can be programmed to send alarm and restore reports as soon as they occur, or wait until the siren time has
expired.
(Loc. 37, pg. 19)
Internal Event Log
Up to 185 events can be stored in memory along with the date and time of the event. These events can later be viewed
through downloading or on an LCD keypad.
All reportable events report to the log.
Keypad Activated Panics
The NX-6 has three keypad activated panics that will send reports to the central station: Auxiliary 1 (Fire), Auxiliary 2
(Medical), and Keypad Panic. Auxiliary 1 will activate the steady (Fire) siren, Auxiliary 2 will sound the keypad, and the
Keypad Panic can be programmed to be silent or audible (sound siren).
(Loc. 23, pg. 17)
Keypad Sounder Control
The NX-6 can be programmed to sound the keypad sounder for certain events.
(Loc. 39, pg. 20)
Keypad Tamper
If enabled, the NX-6 will disable the keypad for 60 seconds and communicate a tamper signal to the central station if 30
keypresses are entered without producing a valid code.
(Loc. 23, pg. 17)
Keyswitch Arm/Disarm
Any zone on the NX-6 can be programmed as a keyswitch zone. If this is done, a momentary short on this zone will
arm/disarm the control. If opening/closing reports are sent, the user code will be 99.
(See "Default Zone
Configurations", pg. 18)
LED Extinguish
This feature will extinguish all LED
=
s on the keypad, except the "Power" LED, after 60 seconds without a keypress.
Pressing any numeric key will illuminate all LED
=
s.
(Loc. 23, pg. 17)
Local Programming Lockout
This feature will disable programming of all locations or specified locations from the keypad.
(Loc. 21, pg. 16)
Log Full Report
A report can be sent to the central station when the event log is full.
(Loc. 37, pg. 19)
Lost Clock Service Light
The NX-6 can be programmed to illuminate the "Service" LED when the internal clock has an invalid time due to power
loss.
(Loc. 37, pg. 19)
Manual Test
The NX-6 can be programmed to perform a bell and/or communicator test when [
r
]-[
4
] is entered while the system is
in the disarmed state.
(Loc. 37, pg. 19)
On-Board Zone Disable
All hardwire zones on the NX-6 panel can be disabled to make a completely wireless alarm system.
(Loc. 37, pg. 19)