SLOW FORMAT COMMUNICATOR CODES
LOCATIONS 56- 83 ARE ONLY USED WHEN REPORTING EVENTS TO A PAGER OR USING A SLOW FORMAT
SUCH AS 4+2. WHEN USING CONTACT ID OR SIA, THERE IS NO NEED TO PROGRAM THESE LOCATIONS.
LOCATION 56
RESTORE
2 segments, numerical data
Location 56 contains the event code for a zone "Restore" for a 4+2 format. The digit programmed in this location will be
sent as the tens digit in place of the alarm event code.
The zone ID will always be reported as the ones digit of the
zone number (i.e. 9 for zone 9).
Any segment left as "0" will follow the Segment 1 selection.
Segment 1 =
Partition #1 Restore Code
Segment 2 =
Partition #2 Restore Code
LOCATION 57
BYPASS
2 segments, numerical data
Location 57 contains the event code for a zone "Bypass" for a 4+2 format. The digit programmed in this location will be
sent as the tens digit.
The zone ID will always be reported as the ones digit of the zone number (i.e. 9 for
zone 9).
Any segment left as "0" will follow the Segment 1 selection.
Segment 1
= Partition #1 Bypass Code
Segment 2 =
Partition #2 Bypass Code
LOCATION 58
TAMPER
2 segments, numerical data
Location 58 contains the event code for a zone "Tamper" for a 4+2 format. The digit programmed in this location will be
sent as the tens digit.
The zone ID will always be reported as the ones digit of the zone number (i.e. 9 for
zone 9).
Any segment left as "0" will follow the Segment 1 selection.
Segment 1
= Partition #1 Tamper Code
Segment 2 =
Partition #2 Tamper Code
LOCATION 59
TROUBLE
2 segments, numerical data
Location 59 contains the event code for a zone "Trouble" for a 4+2 format. The digit programmed in this location will be
sent as the tens digit.
The zone ID will always be reported as the ones digit of the zone number (i.e. 9 for
zone 9).
Any segment left as "0" will follow the Segment 1 selection.
Segment 1 =
Partition #1 Trouble Code
Segment 2 =
Partition #2 Trouble Code
LOCATION 60
SENSOR LOW BATTERY
2 segments, numerical data
Location 60 contains the event code for a zone "Sensor Low Battery" for a 4+2 format. The digit programmed in this
location will be sent as the tens digit.
The zone ID will always be reported as the ones digit of the zone number
(i.e. 9 for zone 9).
Any segment left as "0" will follow the Segment 1 selection.
Segment 1
= Partition #1 Sensor Low Battery Code
Segment 2
= Partition #2 Sensor Low Battery Code
LOCATION 61
SENSOR MISSING
2 segments, numerical data
Location 61 contains the event code for a zone "Sensor Missing" for a 4+2 format. The digit programmed in this location
will be sent as the tens digit.
The zone ID will always be reported as the ones digit of the zone number (i.e. 9
for zone 9).
Any segment left as "0" will follow the Segment 1 selection.
Segment 1
= Partition #1 Sensor Missing Code
Segment 2
= Partition #2 Sensor Missing Code
LOCATION 62
DURESS
2 segments, numerical data
Location 62 contains the tens and ones digits that will be sent for a 4+2 format if the Duress code is enabled in location
44. Segment 1 contains the tens digit, segment 2 contains the ones digit.
LOCATION 63
KEYPAD AUXILIARY 1
2 segments, numerical data
Location 63 contains the tens and ones digits that will be sent for a 4+2 format if the keypad "Auxiliary 1" (FIRE) is
enabled in the partition feature selection. Segment 1 contains the tens digit, segment 2 contains the ones digit.
LOCATION 64
KEYPAD AUXILIARY 2
2 segments, numerical data
Location 64 contains the tens and ones digits that will be sent for a 4+2 format if the keypad "Auxiliary 2" (MEDICAL) is
enabled in the partition feature selection. Segment 1 contains the tens digit, segment 2 contains the ones digit.