Page 13
LOCATION 3
DIAL ATTEMPTS/BACKUP CONTROL PHONE # 1
2 segments, numerical data
Segment 1
Dial attempts:
Location 3, Segment 1 is used to enter the number of dial attempts (1 to 15 Attempts)
the communicator will make to Phone #1 before ending the notification process. Factory default is "8" and the
communicator will make eight (8) attempts to the first number.
Segment 2
Phone #1 Backup Control:
Programming a "
0
" in Segment 2 of this location will cause the NX-6 to
make the designated number of attempts to Phone #1 and #2 before setting the "Fail To Communicate" condition and
stop reporting. Programming a "
1
" in this segment will cause the NX-6 to stop trying to communicate after the
designated number of attempts have been made to Phone #1. If a "
2
" is programmed in this segment, it will cause the
NX-6 to make the dial attempts in increments of two. The first two attempts will be made to Phone #1, the next two
attempts to Phone #2, then repeating until the total number of attempts designated in Segment 1 is completed.
COMMUNICATOR FORMAT SELECTIONS
DATA
FORMAT
DESCRIPTION
0
Local
Communicator is disabled
1
Universal 4+2
Two digit event code 1800hz transmit 2300hz handshake double round parity 40pps
2
3+1 fast (or 4+1)
One digit event code 1900Hz transmit 1400Hz handshake double round parity 20pps
3
Reserved
Reserved
4
Pager
3 digit event code DTMF transmission
5
3/1 or 4/1 slow
1800hz transmit 2300hz handshake double round parity 20 p.p.s. hex capability
6
3/1 or 4/1 slow
1800hz transmit 1400hz handshake double round parity 20 p.p.s. hex capability
7
3/1 or 4/1 fast
1800hz transmit 2300hz handshake double round parity 40 p.p.s. hex capability
8
3/1 or 4/1 fast
1800hz transmit 1400hz handshake double round parity 40 p.p.s. hex capability
9
3/1 or 4/1 fast with
parity
1800hz transmit 2300hz handshake single round w/parity 40 p.p.s. hex capability
10
3/1 or 4/1 fast with
parity
1800hz transmit 1400hz handshake single round w/parity 40 p.p.s. hex capability
11
4+2 express
Two-digit event code DTMF transmission
12
4+2 fast
Two-digit event code 1900hz transmit 1400hz handshake double round parity 20
p.p.s.
13
Ademco Contact ID
DTMF (see pages 37-38)
14
SIA
FSK (see pages 37-38)
15
Custom format
(See location 18, page 16)
LOCATION 4
EVENTS REPORTED TO PHONE # 1
2 segments, feature selection
Phone #1 has two programming locations that are used to select which events are reported to this phone number.
Location 4 is used to select which events are reported to Phone #1. Location 5 is used to select which partitions are
reported to Phone #1. If dual or split reporting is not desired, location 4 should be used to select all events to Phone
#1 and location 5 should be left at the factory default of "0". If dual or split reporting is desired, and the split is based on
the event type (such as alarm, open/close, etc.), location 4 should be used to select only those events that should be
reported to Phone #1 and location 5 should be left at the factory default of "0". If dual or split reporting is desired, and
the split is based on partition, location 4 should be programmed as a "0" and location 5 should be used to select those
partitions that should be reported to Phone #1. If no events should be reported to Phone #1, both locations should be
programmed as "0" (disabling all options).
Use Table 1.1 on page 14 to identify the events to be reported for
Phone #1.