![GE NetworX NX-6 Installation And Startup Download Page 29](http://html.mh-extra.com/html/ge/networx-nx-6/networx-nx-6_installation-and-startup_123019029.webp)
Page 27
PARTITIONING CODES & FEATURES
LOCATIONS 88-91 ARE FOR PROGRAMMING DIFFERENT ACCOUNT CODES AND/OR FEATURES FOR EACH
PARTITION. IF A LOCATION IS NOT PROGRAMMED, THE FEATURE FOR PARTITION 1 AND ACCOUNT CODE
FOR THE PHONE NUMBER WILL BE USED.
LOCATION 88
ACCOUNT CODE FOR PARTITION 1
6 segments, numerical data
Location 88 contains the account code sent when partition 1 is reported.
If location 88 is left unprogrammed (all
A
10"s), then the account code corresponding to the phone number dialed will be used.
If the account code is
less than six digits, program a
A
10" in the segment immediately after the last digit of the account code. If the account
code is 6 digits long, program all 6 segments.
LOCATION 89
ACCOUNT CODE FOR PARTITION 2
6 segments, numerical data
Location 89 contains the account code sent when partition 2 is reported.
If location 89 is left unprogrammed (all
A
10"s), then the account code corresponding to the Phone number dialed will be used.
If the account code is
less than six digits, program a
A
10" in the segment immediately after the last digit of the account code. If the account
code is 6 digits long program all 6 segments.
LOCATION 90
PARTITION 2 FEATURES & REPORTING ENABLE
3 segments, feature selection
Location 90 is used to enable certain features that can be accessed or are visible to the user from the keypad of the
system. In addition, certain communicator reports are enabled in this location. Each of these features can be enabled
by partition. This location contains 3 segments, with eight possible features per segment. Refer to Location 23,
Segments 1,2, and 3 (page 17) for the feature selections.
If all segments are blank (nothing enabled), the
features for partition 1 will be used.
LOCATION 91
PARTITION 2 ENTRY EXIT TIMERS
4 segments, numerical data
Location 91 is used to enter in seconds the Entry and Exit times. There are 2 separate entry and exit times. Valid
entries are 10-255 seconds.
If all segments are
A
0", the entry and exit times for partition 1 will be used.
Segment 1
Entry time 1
Entry time that will be used when a Delay 1 zone type initiates an entry delay.
Segment 2
Exit time 1
Exit time that will be used for all zones designated as Delay 1.
Segment 3
Entry time 2
Entry time that will be used when a Delay 2 zone type initiates an entry delay.
Segment 4
Exit time 2
Exit time that will be used for all zones designated as Delay 2.