Page 31
LOC PG
DESCRIPTION
DEFAULT
PROGRAMMING DATA
27
19 ZONES 9-16, ZONE TYPES
6-6-6-6-6-6-6-6
__ __ __ __ __ __ __ __
ZONES 9-16, PARTITION SELECTION (Segment 1=Zone 9 thru Segment 8=Zone 16)
28
19
Segment #1
1 - Partition #1
“
2 - Partition #2
“
Segment # 2
1 - Partition #1
‘
2 - Partition #2
‘
Segment #3
1 - Partition #1
“
2 - Partition #2
“
Segment #4
1 - Partition #1
“
2 - Partition #2
“
Segment #5
1 - Partition #1
“
2 - Partition #2
“
Segment #6
1 - Partition #1
“
2 - Partition #2
“
Segment #7
1 - Partition #1
“
2 - Partition #2
“
Segment #8
1 - Partition #1
“
2 - Partition #2
“
SIREN AND SYSTEM SUPERVISION
Segment #1
1 -
2 -
3 -
4 -
5 -
6 -
7 -
8 -
Siren sounds for telephone line cut while armed
“
Siren sounds for telephone line cut while disarmed
“
Siren blast at arming
“
Siren blast at exit delay expiration
“
Siren blast at closing kissoff
“
Siren sounds during a cross zone verification time
“
Siren sounds for a tamper
“
Siren blast one time for keyswitch arming, two times for disarming
“
(
NOTE
: This feature must be disabled for SIA
CP-01 installations.)
Segment #2
1 -
2 -
3 -
4 -
5 -
6 -
7 -
8 -
Convert siren driver to voltage out
“
Siren sounds for expander trouble (required for U.L.)
“
Immediate restore by zone
“
Dynamic battery test performed upon arming
“
Battery missing test performed every 12 seconds
“
Manual bell test performed during [
r
]-[4] test function
“
Manual communicator test performed during [
r
]-[4] test function
“
Box tamper enabled.
“
Segment #3
1 -
2 -
3 -
4 -
5 -
6 -
7 -
8 -
Box Tamper report enabled
“
AC Fail report enabled
“
Low Battery report enabled
“
Auxiliary power over current report enabled
“
Siren supervision report enabled
“
Telephone Line Cut report enabled
“
Reserved.
Expander trouble report enabled
“
Segment #4
1 -
2 -
3 -
4 -
5 -
6 -
7 -
8 -
Failure To Communicate report enabled
“
Log Full report enabled
“
Autotest report enabled
“
Start and End Programming report enabled
“
End Download report enabled
“
Sensor Low Battery report enabled
“
Sensor Missing report enabled
“
Reserved.
Segment #5
37
19
1 -
2 -
3 -
4 -
5 -
6 -
7 -
8 -
Lost Clock service LED enable
“
Enables Zone Doubling for zones 7-12 (requires NX-200 Zone Doubling Kit)
“
Disables on-board zones
“
Enables two trips on the same cross-zone to activate the alarm
“
Disables bypass reports for force armed zones
“
Reserved
Clock uses internal crystal
“
Disable Temporal Siren on Fire (
must NOT disable for UL systems
)
“
38
20 SWINGER SHUTDOWN COUNT
1
_