Page 32
LOC PG
DESCRIPTION
DEFAULT
PROGRAMMING DATA
KEYPAD SOUNDER CONTROL
39
20
1 - Keypad sounds for Telephone Line Cut when in the Armed state
“
2 - Keypad sounds for Telephone Line Cut when in the Disarmed state
“
3 - Keypad sounds upon AC Power Failure
“
4 - Keypad sounds upon Low Battery Detection
“
5 - Keypad sounds during Cross Zone Trip Time
“
6 - Keypad sounds for Tamper Alarm
“
7 - Reserved.
8 - Keypad sounds for expander trouble (required for UL)
“
SYSTEM TIMERS
Seg #
40
20
1 - Dynamic Battery Test duration (0-255 minutes)
2 - AC Failure report delay (0-255 minutes)
3 - Power Up Delay (0-60 seconds)
4 - Siren Time (1-254 minutes)
5 - Telephone Line Cut delay (0-255 seconds)
6 - Cross Zone Time (0-255 minutes)
7 - Chime Time in 50 mS increments (0-255 mS)
8 - Dialer delay (15-255 seconds)
9 - Fire Alarm Verification Time (120-255 seconds)
10 - Listen-In Time (0-255 seconds)
0
5
60
8
0
5
3
30
0
0
__
__
__
__
__
__
__
__
__
__
SPECIAL FEATURES
41
21
1 - Enables 6-digit code option -
B
all Arm/Disarm/
=
Go To Program
=
codes require 6 digits
“
2 - Requires valid user code entry for [
r
]-[9]-[8] and [
r
]-[9]-[9] functions to work
“
3 - Enable Auto Cancel / Abort
“
4 - Enable Walk-Test Mode
“
5-8 Reserved.
42
21 GO TO PROGRAM CODE
9-7-1-3-0-0
_ _ _ _ _ _
GO TO PROGRAM CODE PARTITION AND AUTHORIZATION
Segment #1
1 - Reserved.
2 - Enables "Go To Program Code" as an arm only code
“
3 - Enables "Go To Program Code" as an arm only after closing
“
4 - Enables "Go To Program Code" as a master arm/disarm code (can change user codes)
“
5 - Enables "Go To Program Code" as an arm/disarm code
“
6 - Enables "Go To Program Code" to bypass zones
“
7 - Enables "Go To Program Code" opening and closing reports
“
8 - Reserved.
Segment #2
43
21
1 -
2 -
Enables "Go To Program Code" for partition #1
Enables "Go To Program Code" for partition #2
44
21 DURESS
CODE
15-15-15-15-15-15
__ __ __ __ __ __
AUXILIARY OUTPUTS 1-4 PARTITION SELECTION
45
21
Segment #1
1 - Partition #1
“
2 - Partition #2
“
Segment #2
1 - Partition #1
“
2 - Partition #2
“
Segment #3
1 - Partition #1
“
2 - Partition #2
“
Segment #4
1 - Partition #1
“
2 - Partition #2
“
AUXILIARY OUTPUTS 1-4 SPECIAL TIMING
(Segment 1 = Aux 1, Segment 4= Aux 4)
Segments
1 2 3 4
46
21
1 - Auxiliary output timed in minutes
2 - Auxiliary output to latch
3 - Auxiliary output to stop timing upon user code entry
4 - Auxiliary output to activate only between closing and opening time
5 - Auxiliary output to activate only between opening and closing time
6 - Invert auxiliary output ( 0 volts going to 12 volts when activated)
7 - Reserved
8 - Reserved
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
“
AUXILIARY OUTPUT #1, EVENT & TIME
47
22
Segment #1:
Program the event number for output #1
Segment #2:
Program the timing for output #1
0=Burglary alarm
10 seconds
___
___