![GE NetworX NX-6 Installation And Startup Download Page 23](http://html.mh-extra.com/html/ge/networx-nx-6/networx-nx-6_installation-and-startup_123019023.webp)
Page 21
LOCATION 41
SPECIAL FEATURES
1 segment, feature selection
â
On enables the 6-digit code option. If 6-digit option is enabled, all arm/disarm codes and
the "Go To Program Code" are 6 digits. If this option is enabled, the default user #1 code
is [
1
]-[
2
]-[
3
]-[
4
]-[
5
]-[
6
].
NOTE: IF YOU ENABLE THIS OPTION, VERIFY THAT THE
"GO TO PROGRAM CODE" IS A 6-DIGIT CODE BEFORE EXITING PROGRAMMING.
ã
On requires code entry for [
r
]-[
9
]-[
8
]
A
Call back for download
@
and [
r
]-[
9
]-[
9
]
A
Answer
incoming call for download
@
functions.
ä
On enables
A
Auto Cancel/Abort
@
. Refer to feature definitions beginning on page 3.
å
On enables
A
Walk-Test Mode
@
. Refer to feature definitions beginning on page 3.
Ò
-
é
Reserved.
LOCATION 42
GO TO PROGRAM CODE
6 segments, numerical data
Location 42 contains the "Go To Program Code". This location contains either a 4 or 6-digit code.
If the 6-digit code
option is enabled in Location 41, this code must contain six (6) digits.
If this option is not enabled in location 41, the last
2 segments (digits) will be ignored. With the NX-6 disarmed, the "Go To Program Code" can be used to enter the
Program Mode.
LOCATION 43
GO TO PROGRAM CODE PARTITION AND
AUTHORIZATION
2 segments, feature selection
The "Go To Program Code" can be used as a standard arm/disarm code. When using the code to arm or disarm, the user
ID is 255. (This code may not be changed in the Run Mode.)
Segment 1
â
Reserved.
ã
On enables "Go To Program Code" as an arm only code.
ä
On enables "Go To Program Code" as an arm only after closing.
å
On enables "Go To Program Code" as a master arm/disarm code (can change user codes)
æ
On enables "Go To Program Code" as an arm/disarm code.
ç
On enables "Go To Program Code" to bypass zones.
è
On enables "Go To Program Code" opening and closing reports.
é
Reserved.
Segment 2
â
On enables the "Go To Program Code" for Partition #1.
ã
On enables the "Go To Program Code" for Partition #2.
LOCATION 44
DURESS CODE
6 segments, numerical data
Location 44 contains the "Duress" code. This Location contains either 4 or 6 digits.
If the 6-digit code option is enabled
in Location 41, this code must contain six (6) digits.
If the 6-digit option is not enabled in location 41, the last 2 digits
will be ignored.
If the duress code is programmed, it will work for all partitions.
LOCATION 45
AUXILIARY OUTPUT, PARTITION SELECTION
4 segments, feature selection
Location 45 is used to select which partition(s) the events must occur in before the output will activate. Location 45 has
4 segments. Segment 1 corresponds to Output 1, and Segment 4 corresponds to Output 4.
Segments
1 - 4
â
Partition #1
ã
Partition #2
LOCATION 46
AUXILIARY OUTPUT, SPECIAL TIMING
4 segments, feature selection
Location 46 contains special timing feature activation for the four auxiliary outputs. Segment 1 corresponds to Auxiliary
Output 1, Segment 4 corresponds to Auxiliary Output 4.
Segments
1 - 4
â
On if output should be timed in minutes; Off if timed in seconds.
ã
On if output should latch; Off if output should be timed.
ä
On if output should stop timing upon code entry; Off if the output should continue to time
upon code entry.
å
On if output should only activate between the closing and opening time in loc. 52 and 53.
æ
On if output should only activate between the opening and closing time in loc. 52 and 53.
ç
On if output should be inverted (0 volts going to 12 volts when activated).
è
Reserved.
é
Reserved.