![GE NetworX NX-6 Installation And Startup Download Page 16](http://html.mh-extra.com/html/ge/networx-nx-6/networx-nx-6_installation-and-startup_123019016.webp)
Page 14
Table 1.1
Segment 1
1
Alarms and Alarm Restores
2
Opening and Closings
3
Zone Bypass and Bypass Restores
4
Zone Trouble and Trouble Restores
5
Power Fail, Low Battery, Power Restore, and Low Battery Restore
6
Bell Cut , Telephone Line Cut, Bell Cut Restore, Telephone Line Restore
7
Test Reports
8
Start and End programming, Download complete
Segment 2
1
Zone and Box Tamper and Tamper Restore
2
Auxiliary Power Overcurrent and Restore
3
Wireless Sensor Missing and Restore
4
Wireless Sensor Low Battery and Restore
5
Expander Trouble and Restore
6
Fail To Communicate
7 & 8
Reserved
LOCATION 5
PARTITIONS REPORTED TO PHONE #1
1 segment, feature selection
Location 5 is used when events to be reported to a phone number are based upon the partition regardless of the event.
Program a
A
1" for Partition 1, and a
A
2" for Partition 2. If this location is used, location 4 should be "0".
LOCATION 6
PROGRAMMING PHONE #2
20 segments, numerical data
Phone #2 is programmed in location 6. A "14" indicates the end of the phone number. Delays of four seconds can be
programmed at any point in the phone number by programming a "13" in the appropriate segment. If tone dialing is
desired, program a "15" in the segment where tone dialing should begin. If the entire number should be tone dialing,
program a "15" in the first segment. Program an
A
11" for a
A
r
@
, and a
A
12" for a
A
#
@
.
Caution
: A call-waiting cancel on a
non- call waiting line will prevent successful connection to the central station.
LOCATION 7
ACCOUNT CODE FOR THE PHONE #2
6 segments of numerical data
The account code sent when Phone #2 is dialed is programmed in location 7. Program a
A
10" in the segment
immediately after the last digit of the account code. If the account code is 6 digits long, program all 6 segments. If this
location is left unprogrammed, account code 1 will be used when the second phone number is dialed.
LOCATION 8
COMMUNICATOR FORMAT FOR PHONE # 2
1 segment, numerical data
Location 8 contains the communicator format used to transmit to the receiver connected to Phone #2. Consult the
instruction manual for your central station receiver to determine which format is compatible, and select from the 15
formats listed on page 13. If you require a format other than those listed, review the override options described in
Location 18 to build the appropriate format. A "15" must be programmed in location 8 in addition to the entries in
location 18 in order to create a special format. If this location contains a "0", format 1 will be used when Phone #2 is
dialed.
LOCATION 9
DIAL ATTEMPTS/BACKUP CONTROL PHONE #2
2 segments, numerical data
Segment 1
Dial attempts:
Segment 1 of Location 9 is used to enter the number of dial attempts (1 to 15 attempts)
the communicator will make to Phone #2 before ending the notification process. Factory default is "0" and the
communicator will make the same number of attempts as those programmed in location 3.
Segment 2
Phone #2 Backup Control:
Programming a "
0
" in Segment 2 of this location will cause the NX-6 to
make the designated number of attempts to Phone #2 and #1 before setting the "Fail To Communicate" condition and
stop reporting. Programming a "
1
" in this segment will cause the NX-6 to stop trying to communicate after the
designated number of attempts have been made to Phone #2. If a "
2
" is programmed in this segment, it will cause the
NX-6 to make the dial attempts in increments of two. The first two attempts will be made to Phone #2, the next two
attempts to Phone #1, then repeating until the total number of attempts designated in Segment 1 is completed.