– 30 –
From the rear of the unit, remove the 6 hex-
9.
head screws from the channel cover and
remove the cover.
Remove the 4 hex-head screws from the unit
10.
compartment cover and remove that cover.
Lift the cabinet top off the unit and stand it on
11.
the
fl
oor near the rear of the unit.
Remove the hex-head screw from the water
12.
recirculation pump shield and remove the shield.
Pull out on the left and right water distributor
13.
retainers and remove the tabs from the slots in
the evaporator.
Disconnect the hose from the water distributor
14.
and remove the water distributor.
Remove the 4 Phillips-head screws from the
14.
evaporator, and then carefully lift the evaporator
just high enough to remove the 2 right spacers.
Lift the cabinet top and position it forward on
8.
top of the unit, and then remove the permagum
from around the electrical throughput.
(Continued next page)
Remove Permagum
Note:
In the photo above, the rear channel cover has
been removed for clarity.