From the back of the unit, remove the 4 hex-
6.
head screws from the unit compartment cover
and remove the cover.
Remove the two 5/16” screws from the rear of
7.
the cabinet.
Note:
If the unit you are servicing is not equipped
with an internal drain pump, skip the next step.
Disconnect the inlet tube and the vent tube from
8.
the internal drain pump.
Vent Tube
Inlet Tube
Tilt the front of the cabinet back until you can
9.
access the 2 side screws on the condenser fan
motor shroud, and secure the cabinet so that it
cannot tip forward or backward.
Disconnect the wire connector from the
10.
condenser fan motor.
Remove the 4 screws (2 bottom and 2 side)
11.
from the condenser fan motor shroud. Slide the
shroud assembly back towards the compressor,
and then lift and remove the assembly from the
unit.
Remove condenser fan motor blade by pulling
12.
the fan blade straight off the shaft.
Note:
Make sure when reinstalling the fan blade
that the blade is seated completely on the motor
shaft.
Remove the 2 hex-head screws from the
13.
condenser fan motor and remove the motor
from the shroud.
Disconnect