– 26 –
Hot Gas Solenoid
To remove the hot gas solenoid:
Tip the cabinet back and securely prop it up to
1.
access the hot gas valve solenoid.
Disconnect the 2-wire connector from the
2.
solenoid terminals.
Disconnect
Remove the 7-mm hex-head screw from the
3.
solenoid and lift the solenoid off the hot gas
valve.
Measured Fill Water Valve
To remove the measured fi ll water valve:
Turn the water supply off to the icemaker.
1.
Remove the 4 hex-head screws from the front
2.
panel and remove the panel.
Remove the 2 hex-head screws from the
3.
measured
fi
ll water valve bracket.
Measured Fill Water Valve
Note:
Place a pan or towel under the valve to catch
the water.
Disconnect the water inlet and outlets tubing
3.
from the quick-disconnect
fi
ttings on the
measured
fi
ll water valve.
Disconnect the 2 electrical connectors from the
4.
valve.
Outlet Tube
Inlet Tube
Disconnect