– 39 –
Problem
Probable Cause
Test Procedure - Action
Too much ice in bin
Defective bin thermistor
Replace
Banging sound
The slab dropping off the plate
and ice dropping from the cutter
grid into an empty bin are normal
sounds
Noisy
Grinding, cavitating sound
The reservoir is empty. Look for a
partially released slab,
interference with cutter grid, etc.,
and clean the evaporator plate.
See procedure on
4-21
Grinding, cavitating sound
from recirculation pump
If the reservoir is full, replace the
pump
Noisy drain pump
Repair or replace
Ice freezing together in the
bin
Normal
This is normal with low customer
usage
Cloudy, poor tasting ice
Poor water quality
See chart on
4-2 & 4-3
Off LED flashing 2 blinks
Open or disconnected bin
thermistor or thermistor wiring
Test thermistor and wiring harness
or reconnect
Off LED flashing 3 blinks
Defective, loose, or mis-
positioned evaporator
thermistor
Test thermistor and wiring harness
or reconnect
-