– 28 –
Remove the wires from the ground terminal,
7.
the overload protector terminal, and the relay
terminal.
Pull the overload protector and relay from the
8.
compressor pins.
Pull the 2 clips off the rear studs of the
9.
compressor.
Tip the front of the cabinet back and prop it up.
10.
Access the sealed system and discharge the
11.
refrigerant into an approved recovery system.
Cut the suction and discharge lines from the
12.
compressor.
Caution:
Do not use a torch to remove the drier
fi
lter.
Cut the drier
fi
lter from the system.
13.
Unbraze the compressor suction and discharge
14.
joints from the tubing.
Pull the clips off the compressor mounting studs.
15.
Lift the compressor off the 4 mounting studs
16.
and remove it from the unit.
Remove the 4 metal spacers and rubber
17.