– 7 –
Refrigeration System
The refrigeration system is very similar to the
system used in other refrigeration appliances. The
refrigerant used in this unit is R134a.
There are 2 very important additions to the
refrigeration system in this Icemaker: the
hot gas
valve
and the
condenser accumulator tube
.
The
1.
hot gas valve
allows high pressure
refrigerant gas to bypass the condenser and
fl
ow through the condenser accumulator tube.
Hot gas pushes liquid refrigerant through
2.
the
condenser accumulator tube
into
the evaporator, helping to evenly heat the
evaporator plate so that the ice slab releases
quickly and evenly.
Heat Exchanger
Condenser
Accumulating
Tube
Path of warm liquid refriger-
ant pushed by high-pres-
sure refrigerant gas
Evaporator
Condenser
Drier
Suction
Tube
Compressor
Accumulator
Capillary Tube
High-Pressure
Refrigerant Gas
Warm Liquid
Refrigerant
Low-Pressure
Refrigerant Gas
Hot Gas
Valve