Positioner Mounting and Orientation
Camflex II, Varimax, MiniTork II, Ball II, and HPBV
The positioner is mounted to an intermediate plate (171) by two screws (29) and lockwashers (30)
with the gauges nearest the actuator on Camflex and Varimax (Figure 8) and with gauges away
from actuator on Ball II (Figure 9), MiniTork II (Figure 9), and HPBV (Figure 10). The intermediate
mounting plate (171) is held by two flat-head screws (172) to the bracket.
NOTE
The cam take-off hole must be centered about the shaft.
Table 3: Mounting Parts Reference
Ref.
No.
Description
Ref.
No.
Description
29
Socket Head Screw
172
Mounting Plate Screws
171
Mounting Plate
30
Lockwashers
NOTE
The remainder of the mounting kit parts are used to before
tightening mounting screws. assemble the cam to the actuator.
See “Mounting Cam Coupling” on page 44.