Freezer Model:FHV5SGWW/FHV7SGWW
40
MAINTENANCE SERVICE AND TROUBLE SHOOTING
Maintenance Service and Trouble Shooting
⑧
Switch off motor.
(3) Filling
①
Determine the filling quantity first according to the freezer being
repaired. (Each small mark of the liquid tube is 25g, each big mark is 100g).
②
Open all related valves.
③
When the liquid level has reached filling quantity, close valves.
(4) Test run
①
After filling, turn on power to freezer for test run. Observe the unit
operation.
②
Switch off power.
12.6 Freezer noise
12.6.1 Freezer noise sources
Freezer noise comes from the expanding with heat and contracting with
cold of compressor, evaporator or condenser; from the contacting or
resonance of pipes; from the flowing of refrigerant; or from the vibration of
freezer because the floor is not level, etc.