(3) The cover temperature of The evaporator can be as low as
-30
℃
it will feel sticky when touching. If you
’
d like to touch,
please move your hand over it quickly, otherwise your hand will
be stuck.
(4) At normal operation of freezer, the temperature of filter dryer
cover is similar to room temperature, only a little warmer. If the
cover temperature is much higher or lower than that of
environment, and there is frost, there must be problem with the
refrigeration system.
Touching the above mentioned parts, if there is big temperature
difference compared with normal, there must be problem and
further decision should be made.
12.1.6 System noise repair
Normally there are two kinds of freezer noise, one is the natural
noise of compressor and fan, and the other is the resonance
noise or structural noise. The natural noise of compressor and
fan is controlled within a standard range, if the range is exceeded,
the compressor or fan needs to be repaired or changed. The
resonance or structural noise can be handled as follows: