SECTION 15
EVT PRO 2.0
®
-
MOUNTING THE BRACKET TO A VALVE
Step 1
Select the software indicated Hydraulic
Lifting Cylinder
and install on bracket.
Tighten the locking ring till just snug.
Step 2
Select the correct Spindle Adapter for the
valve and install onto the valve spindle.
NOTE: Use of the Spindle Adapters is
highly recommended to ensure proper
contact area for the claw fingers to
adequately grasp.
Step 3
Turn the brass thumb screws to open the
bracket base and fit it onto the valve.
Tighten the thumbscrews for a secure fit.
Step 4
Select the correct load cell as indicated by
the software.
Step 5
Select the correct Load Cell Claw device
which matches the load cell.
Screw the
Claw device onto the load cell as shown.
NOTE: When placing the Bracket Assembly onto the valve, make sure to verify that the
columns and the bracket are aligned with the spindle. A misaligned Bracket Assembly
can cause the claws to slip off to one side during testing.
EVT PRO 2.0
®
Operations and Technical Manual (Rev 1.0
– 2016)
NOT FOR COPY OR DISTRIBUTION
Page 18
Summary of Contents for EVT-Pro 2.0
Page 10: ...EVT PRO 2 0 Operations and Technical Manual Rev 1 0 2016 NOT FOR COPY OR DISTRIBUTION Page 6 ...
Page 11: ...EVT PRO 2 0 Operations and Technical Manual Rev 1 0 2016 NOT FOR COPY OR DISTRIBUTION Page 7 ...
Page 57: ...APPENDIX INFORMATION EVT Pro 2 0 Operations and Technical Manual Rev 1 0 2016 ...