Druck ADTS 2XX User Manual
K0451 Issue No. 1
Pt Port
Pressure Mode
Control Range: ................................................................................................................... 35
(1)
to 2767 mbar a
Measure Range: .................................................................................................................. 27.6 to 3500 mbar a
Resolution: ....................................................................................................................................................0.01mbar
Accuracy: .................................................................................................................................................. ±0.35 mbar
Aeronautical Mode
Control Range: .................................................................................................... 20 to 650 kts (0 to 2.8 Mach)
Measure Range: .................................................................................................. 0 to 1000 kts (0 to 10 Mach)
Resolution: ...........................................................................................................................................................0.1 kts
Accuracy: ..........................................................................................................................................................±0.5 kts
6.3 Operating Limits
Default limits
This first set of user defined limits, identified as: USER 1, are enabled when the ADTS 2XX is switched
on.
Alternative Limits
Enter the PIN to access the SETUP LIMITS display. Select one of the preset limits of MAX, STANDARD
and CIVIL or define and enable USER 2 limits. An eight character name/code can replace the USER
2 title.
Preset limits
Name: “MAX”
MIN ALT
-2000 ft
MAX ALT
60,000 ft
MAX ROC
40,000 ft/min
MIN CAS
0.0 knots
MAX CAS
650 knots
MAX MACH
2.7 Mach
MIN Ps1/Ps2
10.90 mbar (0.3219 inHg)
MAX Ps1/Ps2
1355.00 mbar (40.0131 inHg)
MIN Qc
-1355.00 mbar (-40.0131 inHg)
MAX Qc
2490.00 mbar (73.5296 inHg)
MAX Rate Ps1/Ps1
1000.00 mbar/min (29.5300 inHg/min)
MAX Rate Qc
1000.00 mbar/min (29.5300 inHg/min)
ALT CORRECTION
100 ft
ARINC LIMITS
OFF
MAX Ps1 to Ps2 Diff.
84.66 mbar (2.5 inHg)
Summary of Contents for Druck ADTS 2 Series
Page 1: ...GE Sensing Druck Air Data Test Systems Three channel Test Set User Manual K0451 XX ...
Page 2: ... General Electric Company All rights reserved ...
Page 56: ...Druck ADTS 2XX User Manual 44 K0451 Issue No 1 INTENTIONALLY LEFT BLANK ...
Page 66: ...Druck ADTS 2XX User Manual 54 K0451 Issue No 1 INTENTIONALLY LEFT BLANK ...