Revision C
DINAMAP
®
ProCare Monitor Service Manual
2-5
2009381-001
Equipment Overview:
Basic Components
10. Temperature probe cover storage: Box of probe covers is stored here.
11. History button: Press to activate the History mode to view stored patient
data. The most recent entries are displayed first. Press and hold the button
for 2 seconds to clear all entries stored. Refer to the
History
section of this
manual for more information.
12. Print button: Press to print currently displayed values or all stored entries
when in history mode.
13. On/Off button: Controls on/off state of monitor; push for power on and push
again for power off.
14. Temperature probe connector: Temperature probe cable attaches here.
Front Panel
15. Silence icon: when Silence button is pressed after alarm sounds (silence
active), silence icon (bell) lights to indicate that audible alarms have been
silenced for 2 minutes.
16. Systolic window: 3-digit red LED indicates measured systolic BP in mmHg.
17. Diastolic window: 3-digit red LED indicates measured diastolic BP in mmHg.
18. Alarm volume indicator: lights to indicate you are making a change to the
alarm volume.
19. Pulse volume: lights to indicate you are making a change to the pulse
volume.
Summary of Contents for DINAMAP ProCare
Page 2: ......
Page 11: ...Revision C DINAMAP ProCare Monitor Service Manual 1 1 2009381 001 1 Introduction ...
Page 12: ...1 2 DINAMAP ProCare Monitor Service Manual Revision C 2009381 001 For your notes ...
Page 23: ...Revision C DINAMAP ProCare Monitor Service Manual 2 1 2009381 001 2 Equipment Overview ...
Page 24: ...2 2 DINAMAP ProCare Monitor Service Manual Revision C 2009381 001 For your notes ...
Page 39: ...Revision C DINAMAP ProCare Patient Monitor Service Manual 3 1 2009381 001 3 Installation ...
Page 40: ...3 2 DINAMAP ProCare Patient Monitor Service Manual Revision C 2009381 001 For your notes ...
Page 53: ...Revision C DINAMAP ProCare Monitor Service Manual 4 1 2009381 001 4 Maintenance ...
Page 54: ...4 2 DINAMAP ProCare Monitor Service Manual Revision C 2009381 001 For your notes ...
Page 71: ...Revision C DINAMAP ProCare Monitor Service Manual 5 1 2009381 001 5 Troubleshooting ...
Page 72: ...5 2 DINAMAP ProCare Monitor Service Manual Revision C 2009381 001 For your notes ...
Page 78: ...6 2 DINAMAP ProCare Monitor Service Manual Revision C 2009381 001 For your notes ...
Page 99: ...Revsion C DINAMAP ProCare Monitor Service Manual A 1 2009381 001 A Technical Specifications ...
Page 100: ...A 2 DINAMAP ProCare Monitor Service Manual Revision C 2009381 001 For your notes ...
Page 133: ......