Revision C
DINAMAP
®
ProCare Monitor Service Manual
C-7
2009381-001
Electromagnetic Compatibility (EMC):
Electromagnetic Compatibility (EMC): ProCare Monitor
Compliant Cables and Accessories
WARNING
The use of accessories, transducers and cables other than
those specified may result in increased emissions or decreased
immunity performance of the equipment or system.
The table below lists cables, transducers, and other applicable accessories with
which GE Medical Systems claims EMC compliance.
NOTE:
Any supplied accessories that do not affect EMC compliance are not
included.
Part No
Description
Maximum Lengths
Temperature Cables and Probes
2008774-001
Turbo-Temp Oral Probe, Blue
3.0 m / 10 ft
2008775-001
Turbo-Temp Rectal Probe, Red
3.6 m / 12 ft
2016998-001
Dual Temp Cable
20 cm / 8 in
Pulse Oximetry Cables and Sensors
407705-006
Nellcor DuraSensor Reusable Finger Probe
(DS100A)
0.9 m/ 3 ft
2008773-001
Nellcor Interface Cable, OxiSmart, DOC 10
Cable
3.3 m / 11 ft
2009743-001
Masimo PC08 Cable
2.5 m / 8.2 ft
2009745-001
Masimo Finger Sensor, Adult, Reusable
N/A
Accessories
316579-001
AC Cable, Hospital Grade, AHA
3.6 m / 12 ft
2013057-001
Universal AC/DC Adapter
N/A
ILC-1926
Isolated Level Converter
N/A
Summary of Contents for DINAMAP ProCare
Page 2: ......
Page 11: ...Revision C DINAMAP ProCare Monitor Service Manual 1 1 2009381 001 1 Introduction ...
Page 12: ...1 2 DINAMAP ProCare Monitor Service Manual Revision C 2009381 001 For your notes ...
Page 23: ...Revision C DINAMAP ProCare Monitor Service Manual 2 1 2009381 001 2 Equipment Overview ...
Page 24: ...2 2 DINAMAP ProCare Monitor Service Manual Revision C 2009381 001 For your notes ...
Page 39: ...Revision C DINAMAP ProCare Patient Monitor Service Manual 3 1 2009381 001 3 Installation ...
Page 40: ...3 2 DINAMAP ProCare Patient Monitor Service Manual Revision C 2009381 001 For your notes ...
Page 53: ...Revision C DINAMAP ProCare Monitor Service Manual 4 1 2009381 001 4 Maintenance ...
Page 54: ...4 2 DINAMAP ProCare Monitor Service Manual Revision C 2009381 001 For your notes ...
Page 71: ...Revision C DINAMAP ProCare Monitor Service Manual 5 1 2009381 001 5 Troubleshooting ...
Page 72: ...5 2 DINAMAP ProCare Monitor Service Manual Revision C 2009381 001 For your notes ...
Page 78: ...6 2 DINAMAP ProCare Monitor Service Manual Revision C 2009381 001 For your notes ...
Page 99: ...Revsion C DINAMAP ProCare Monitor Service Manual A 1 2009381 001 A Technical Specifications ...
Page 100: ...A 2 DINAMAP ProCare Monitor Service Manual Revision C 2009381 001 For your notes ...
Page 133: ......