92
D90
PLUS
LINE DISTANCE PROTECTION SYSTEM – COMMUNICATIONS GUIDE
MODBUS MEMORY MAP
CHAPTER 2: MODBUS COMMUNICATION
686C
Hybrid POTT 1P Trans Block Reset Delay
0 to 65.535
s
0.001
F001
90
686D
Hybrid POTT 1P Echo Duration
0 to 65.535
s
0.001
F001
100
686E
Hybrid POTT 1P Echo Lockout
0 to 65.535
s
0.001
F001
250
686F
Hybrid POTT 1P Seal In Delay
0 to 65.535
---
0.001
F001
0
6870
Hybrid POTT 1P Ground Directional Overcurrent
Forward
0 to 65535
---
1
F300
0
6871
Hybrid POTT 1P Gnd Directional Overcurrent Reverse 0 to 65535
---
1
F300
0
6872
Hybrid POTT 1P Number of Communication Bits
0 to 2
---
1
F198
0 (1)
6873
Hybrid POTT 1P Rx1
0 to 65535
---
1
F300
0
6874
Hybrid POTT 1P Rx2
0 to 65535
---
1
F300
0
6875
Hybrid POTT 1P Rx3
0 to 65535
---
1
F300
0
6876
Hybrid POTT 1P Rx4
0 to 65535
---
1
F300
0
6878
Hybrid POTT 1P Event
0 to 1
---
1
F102
0 (Disabled)
6879
Hybrid POTT 1P Echo Condition
0 to 65535
---
1
F300
0
687A
Hybrid POTT 1P Weak Infeed
0 to 2
---
1
F199
1 (Enabled)
687B
Hybrid POTT 1P Weak Infeed Condition
0 to 65535
---
1
F300
0
687C
Hybrid POTT 1P Block
0 to 65535
---
1
F300
0
687D
Reserved (3 items)
0 to 1
---
1
F001
0
Pilot Blocking (1P) (Read/Write Setting)
6880
Blocking Scheme 1P Function
0 to 1
---
1
F102
0 (Disabled)
6881
Block 1P Rx Coord Pickup Delay
0 to 65.535
s
0.001
F001
10
6882
Block 1P Transient Block Pickup Delay
0 to 65.535
s
0.001
F001
30
6883
Block 1P Transient Block Reset Delay
0 to 65.535
s
0.001
F001
90
6884
Blocking Scheme 1P Seal In Delay
0 to 65.535
s
0.001
F001
0
6885
Blocking Scheme 1P Gnd Directional Overcurrent Fwd 0 to 65535
---
1
F300
0
6886
Blocking Scheme 1P Gnd Directional Overcurrent Rev 0 to 65535
---
1
F300
0
6887
Blocking Scheme 1P Number of Communication Bits 0 to 2
---
1
F198
0 (1)
6888
Blocking Scheme 1P Rx1
0 to 65535
---
1
F300
0
6889
Blocking Scheme 1P Rx2
0 to 65535
---
1
F300
0
688A
Blocking Scheme 1P Rx3
0 to 65535
---
1
F300
0
688B
Blocking Scheme 1P Rx4
0 to 65535
---
1
F300
0
688D
Blocking 1P Event
0 to 1
---
1
F102
0 (Disabled)
688E
Blocking Scheme 1P Block
0 to 65535
---
1
F300
0
688F
Reserved (2 items)
0 to 1
---
1
F001
0
Autoreclose 1P 3P (Read/Write Setting)
6890
Autoreclose Mode
0 to 3
---
1
F080
3 (3 Pole-B)
6891
Autoreclose Maximum Number of Shots
1 to 4
---
1
F001
2
6892
Autoreclose Block Breaker 1
0 to 65535
---
1
F300
0
6893
Autoreclose Close Time Breaker 1
0 to 655.35
s
0.01
F001
10
6894
Autoreclose Breaker Manual Close
0 to 65535
---
1
F300
0
6895
Autoreclose Function
0 to 1
---
1
F102
0 (Disabled)
6896
Autoreclose Block Time Manual Close
0 to 655.35
s
0.01
F001
1000
6897
Autoreclose 1P Initiate
0 to 65535
---
1
F300
0
6898
Autoreclose 3P Initiate
0 to 65535
---
1
F300
0
6899
Autoreclose 3P TD Initiate
0 to 65535
---
1
F300
0
689A
Autoreclose Multi-Phase Fault
0 to 65535
---
1
F300
0
689B
Autoreclose Breaker 1 Pole Open
0 to 65535
---
1
F300
0
Address Description
Range
Units
Step
Format Default