CHAPTER 1: BEFORE YOU START
D20MX INSTRUCTION MANUAL
GE INFORMATION
17
D20MX applications
Table 2 lists the applications included in the D20MX firmware.
NOTE
* An Application ID containing an “N” (e.g., A009N) signifies a unique application definition
for the D20MX.
† The D20MX version of the application is based on this D20 classic application version.
However, the D20MX version is not identical to the D20 classic version due to minor
changes to improve the robustness and security of the original application.
‡ The version of B009 in SAN0002 is actually based on D20 classic application version 401
but modified to be compatible with the version 310 application definition version.
Ф
The version of B021 in SAN002 is actually based on D20 classic application version 991
but modified to be compatible with the version 912 application definition version.
Table 2: D20MX applications
License
Group
D20MX
Application ID
Base D20 Classic
Application Version †
Application Name
Description
Common Application Definitions
001
A009N
805
PG&E DPA for D20MX
Pacific Gas and Electric (PG&E) data-processing
application (DPA) for remote terminal units
(RTUs).
001
A017N
131
Distributed Network
Protocol V1.00 DCA for
D20MX
Distributed Network
Protocol (DNP) V1.0 Data Link Application.
Required by the Quantum Meter Scanner DCA.
001
A018
120
Quantum Meter Scanner
DCA
The Quantum Meter Scanner DCA obtains data
from one or more Quantum Meters via the DNP
interface.
001
A023N
423
CDC Type I DPA for D20MX The CDC Type I DPA emulates a CDC Type I RTU
A026-1
321
Communication
Watchdog DTA
Reports on the state of communications
between the RTU and a remote device (Data
Translation Application).
A027N
832
SOE Logger DTA for D20MX The Sequence-of-Events Logger DTA processes
sequence of events (SOEs) from any sub-set of
the system digital input and/or analog input
points.
A030
300
Accumulator Freeze DTA
Detects system status point changes and
system accumulator point freezes.
001
A033-5N
211
TEJAS V DPA for D20MX
Emulates a remote terminal unit utilizing the
(Valmet/Metso/Telvent) TEJAS V
communication protocol.
A035
211
Analog Reference DTA
Monitors analog input points and provides the
system database with pseudo analog values
that represent either correctly functioning
analog input hardware (good reference value),
or failed analog input hardware (bad reference
value).
001
A036N
421
ProLogic Executor DTA for
D20MX
Provides user programmable soft logic
automation functionality.
001
A041-1
116
Proportional Integral
Derivative Control DTA
The Proportional, Integral and Derivative (PID)
DTA uses the generally-accepted industry
standard for control of closed loop processes.
A048
210
Status Combination DTA
Provides one ore more DI points, each of which
provides an event-driven logical OR of a set of
mapped system DI points.
A059-0N
911
Modbus DCA for D20MX
Acts as a data concentrator for one or more
Sub-Remote Units (SRUs) using the MODBUS
communication protocol (RTU & ASCII modes).
Summary of Contents for D20MX
Page 10: ...10 GE INFORMATION D20MX INSTRUCTION MANUAL ABOUT THIS DOCUMENT ...
Page 32: ...32 GE INFORMATION D20MX INSTRUCTION MANUAL CHAPTER 1 BEFORE YOU START ...
Page 90: ...90 GE INFORMATION D20MX INSTRUCTION MANUAL CHAPTER 5 CONFIGURING THE SOFTWARE ...
Page 112: ...112 GE INFORMATION D20MX INSTRUCTION MANUAL APPENDIX B STANDARDS PROTECTION ...
Page 116: ...116 GE INFORMATION D20MX INSTRUCTION MANUAL APPENDIX C FREQUENTLY ASKED QUESTIONS ...
Page 148: ...148 GE INFORMATION D20MX INSTRUCTION MANUAL APPENDIX D USING CONFIGPRO WITH D20MX ...
Page 158: ...158 GE INFORMATION D20MX INSTRUCTION MANUAL APPENDIX E SECURE CONNECTION FOR LOGICLINX ...
Page 162: ...162 GE INFORMATION D20MX INSTRUCTION MANUAL APPENDIX F LIST OF ACRONYMS ...
Page 168: ...168 GE INFORMATION D20MX INSTRUCTION MANUAL INDEX ...