Housing Installation
CyberDome Series Installation Manual
8
A06-8SG0/B/April2006/1033921C
Method 1: Installation Into T-Bar Ceilings
A T-bar type ceiling consists of a metal grid, which is used to suspend removable panels.
See
Figure 5
. The panels will be either 24 in. x 24 in. (60.96 cm x 60.96 cm) or 24 in. x 48 in.
(60.96 cm x 121.92 cm). Installation into this type of ceiling requires a KTA-22-6 T-bar Mount-
ing Panel (24 in. x 24 in., i.e., 60.96 cm x 60.96 cm) or a KTA-24-6 T-Bar Support Kit (refer to
Appendix A
).
The KTA-22-6 was formerly the KTA-00-6, and the KTA-24-6 the KTA-10-6.
6-inch Flush-mount Housing Installation
The indoor flush-mount housing can be installed into most types of ceilings, provided there is
sufficient clearance for the unit. See
Figure 4
. The method of installation depends on the type
of ceiling into which the CyberDome is being mounted. Methods are:
•
Method 1 – Into T-bar ceilings
(page 8)
•
Method 2 – Into non-removable false ceilings
(page 11)
•
Method 3 – With superstructure attachment
(page 15)
Figure 4: False Ceiling Clearance
Figure 5: T-Bar Ceiling with Mounting Panel