CyberDome Series Installation Manual
PTZ and Dome Installation
33
A06-8SG0/B/April2006/1033921C
Setting the Site Address DIP Switch
The receiver card mounted on the CyberDome’s pan/tilt assembly contains a multi-position
DIP switch. See
Figure 50
. The switch is used to assign the CyberDome a site number in the
Digiplex system.
To enter the receiver’s site number on the DIP switch:
Step 1)
Determine which position values must be added together to equal the site num-
ber. See
Table 2
and
Figure 51
.
Step 2)
Place the switches that correspond to those values in the ON position.
DIP Switch Position Number
1
2
3
4
5
6
7
8
9
10
11
12
Equivalent Value
1
2
4
8
16
32
64
128
256
512
X
X
X = Not Used
Figure 50: Location of Site Address DIP Switch
Table 2. DIP Switch Positions and Equivalent Values
Figure 51: Building Site Addresses