Appendix C: 8-inch Pendant-mount Housing Installation
CyberDome Series Installation Manual
48
A06-8SG0/B/April2006/1033921C
Step 6)
While pushing the cables and interface connector card back into the pipe, posi-
tion the housing where it can be threaded onto the pipe.
Step 7)
Before threading the housing onto the pipe, rotate it five turns in the counterclock-
wise direction (as viewed from below) to allow for cable twist. Turn the housing
onto the pipe in a clockwise direction until it is tightened securely. See
Figure 68
.
Check to be certain that it is not cross threaded.
CAUTION!
DO NOT undertighten or overtighten the top housing nuts. Leakage or stripped material will result.
Step 8)
Using a 3/8-inch nut driver or socket wrench, securely tighten the three mounting
nuts on top of the housing to a torque of 3 to 5 ft-lb. See
Figure 67
(above).
Step 9)
Proceed to
RS422 Termination
on page 31.
Figure 68: Threading the Housing
Step 4)
If the housing is being installed
outside (W option only), ap-
ply thread sealer to the pipe
to assure that no water enters
the housing.
Step 5)
Bring the housing near the end
of the pipe and insert the in-
terconnect cable from the in-
terface connector card into
the RJ45 jack (as shown in
Fig-
ure 67
).
Figure 67: Inserting the Interconnect Cable