Step 1)
Securely mount the pipe from
which the pendant housing will
be suspended. Remember
that the pipe must be able to
support a 35 lb (15.88 kg)
load.
Step 2)
Feed the video, 24VAC, and
RS422 control cables through
the pipe.
CAUTION!
If the power and RS422 cables are reversed
in step 3 (below), the CyberDome will be dam-
aged.
Step 3)
Make the cable connections
to the interface module (see
Figure 23).
Allow approxi-
mately 3” (7.62 cm) of cable
for connection.
If installing a weatherproof
housing with a heater/fan
E Option, also connect the
heater’s power cable to the
2-pin Molex connector on the
interface connector card.
APPENDIX C: 8-INCH PENDANT HOUSING INSTALLATION
The pendant housing can be mounted using one of two methods:
•
Method 1 – Suspended from a 1.25 in. pipe
(page 47)
•
Method 2 – Attached to a KTA-02-12 Wall Bracket
(page
49)
Method 1: Pipe Installation
The pendant housing contains a 1.25 in. NPT pipe flange for pipe mounting.
Adhere to the following pipe requirements:
•
Use only Schedule 40 pipe.
•
The pipe must be at least 5 in. (12.7 cm) in length to allow for wire connections.
•
The pipe must be reamed inside at the CyberDome end.
•
The pipe must be able to support a 35 lb (15.88 kg) load.
•
For outdoor applications (W option), thread sealer must be applied to the pipe to assure
that no water enters the housing.