GE Multilin
B30 Bus Differential System
B-21
APPENDIX B
B.4 MEMORY MAPPING
B
3879
Field Unit 2 Process Card Port
0 to 7
---
1
F244
4 (H2a)
387A
Field Unit3 Process Card Port
0 to 7
---
1
F244
2 (H3a)
387B
Field Unit 4 Process Card Port
0 to 7
---
1
F244
0 (H4a)
387C
Field Unit 5 Process Card Port
0 to 7
---
1
F244
7 (H1b)
387D
Field Unit 6 Process Card Port
0 to 7
---
1
F244
5 (H2b)
387E
Field Unit 7 Process Card Port
0 to 7
---
1
F244
3 (H3b)
387F
Field Unit 8 Process Card Port
0 to 7
---
1
F244
1 (H4b)
Field Unit CT VT Settings (Read/Write Setting) (6 modules)
3890
Remote Phase CT x Origin 1
0 to 16
---
1
F247
0 (None)
3891
Remote Phase CT x Origin 2
0 to 16
---
1
F247
0 (None)
3892
Remote Ground CT x Origin 1
0 to 16
---
1
F248
0 (None)
3893
Remote Ground CT x Origin 2
0 to 16
---
1
F248
0 (None)
3894
AC Bank Redundancy Type
0 to 2
---
1
F261
1
(Dependabilit
y Biased)
3895
Remote Phase CT 1 Primary
1 to 65000
---
1
F001
1
3896
Remote Phase CT 1 Secondary
0 to 1
---
1
F123
0 (1 A)
3897
Remote Ground CT 1 Primary
1 to 65000
---
1
F001
1
3898
Remote Ground CT 1 Secondary
0 to 1
---
1
F123
0 (1 A)
3899
Remote Phase VT 1 Connection
0 to 1
---
1
F100
0 (Wye)
389A
Remote Phase VT 1 Secondary
25 to 240
---
0.1
F001
664
389B
Remote Phase VT 1 Ratio
1 to 24000
---
1
F060
1
389D
Remote Auxiliary VT 1 Connection
0 to 6
---
1
F166
1 (Vag)
389E
Remote Auxiliary VT 1 Secondary
25 to 240
---
0.1
F001
664
389F
Remote Auxiliary VT 1 Ratio
1 to 24000
---
1
F060
1
38A1
...Repeated for module number 2
38B2
...Repeated for module number 3
38C3
...Repeated for module number 4
38D4
...Repeated for module number 5
38E5
...Repeated for module number 6
Field Unit Contact Inputs (Read/Write Setting) (40 modules)
3900
Field Contact Input 1 ID
---
---
1
F205
"FCI 1"
3906
Field Contact Input 1 Origin
0 to 8
---
1
F256
0 (None)
3907
Field Contact Input 1 Input
1 to 18
---
1
F001
1
3908
Field Contact Input 1 Failsafe Value
0 to 1
---
1
F108
0 (Off)
3909
Field Contact Input 1 Debounce Time
0 to 16
ms
0.5
F001
20
390A
Field Contact Input 1 Events
0 to 1
---
1
F102
1 (Enabled)
390B
...Repeated for Field Contact Input 2
3916
...Repeated for Field Contact Input 3
3921
...Repeated for Field Contact Input 4
392C
...Repeated for Field Contact Input 5
3937
...Repeated for Field Contact Input 6
3942
...Repeated for Field Contact Input 7
394D
...Repeated for Field Contact Input 8
3958
...Repeated for Field Contact Input 9
3963
...Repeated for Field Contact Input 10
396E
...Repeated for Field Contact Input 11
3979
...Repeated for Field Contact Input 12
3984
...Repeated for Field Contact Input 13
398F
...Repeated for Field Contact Input 14
Table B–10: MODBUS MEMORY MAP (Sheet 13 of 60)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Summary of Contents for B30 UR Series
Page 10: ...x B30 Bus Differential System GE Multilin TABLE OF CONTENTS ...
Page 122: ...4 30 B30 Bus Differential System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Page 326: ...5 204 B30 Bus Differential System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 412: ...A 12 B30 Bus Differential System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Page 554: ...D 10 B30 Bus Differential System GE Multilin D 1 IEC 60870 5 104 APPENDIX D D ...
Page 566: ...E 12 B30 Bus Differential System GE Multilin E 2 DNP POINT LISTS APPENDIX E E ...
Page 574: ...F 8 B30 Bus Differential System GE Multilin F 3 WARRANTY APPENDIX F F ...