APPENDIX B
B.4 MEMORY MAPPING
B
IEC 61850 XSWI Configuration (Read/Write Command) (24 modules)
B372
Command to Clear XSWI OpCnt (Operation
Counter)
0 to 1
---
1
F126
0 (No)
IEC 61850 GGIO1 Configuration Settings (Read/Write Setting)
B400
Number of Status Indications in GGIO1
8 to 128
---
8
F001
8
B402
IEC 61850 GGIO1 Indication FlexLogic operands
(128 items)
0 to 4294967295
---
1
F300
0
IEC 61850 Configurable GOOSE Transmission (Read/Write Setting) (8 modules)
B5A0
IEC 61850 Configurable GOOSE Function
(GoEna)
0 to 1
---
1
F102
1 (Enabled)
B5A1
IEC 61850 Configurable GOOSE ID
---
---
---
F209
“GOOSEOut_
x_”
B5C2
Configurable GOOSE Destination MAC Address
---
---
---
F072
0
B5C5
IEC 61850 Configurable GOOSE VLAN Transmit
Priority
0 to 7
---
1
F001
4
B5C6
IEC 61850 Configurable GOOSE VLAN ID
0 to 4095
---
1
F001
0
B5C7
IEC 61850 Configurable GOOSE ETYPE APPID
0 to 16383
---
1
F001
0
B5C8
IEC 61850 Configurable GOOSE ConfRev
(Configuration Revision)
1 to 4294967295
---
1
F003
1
B5CA
IEC 61850 Configurable GOOSE Retransmission
Curve
0 to 3
---
1
F611
3 (Relaxed)
B5CB
Configurable GOOSE Dataset Items for
Transmission
(64 items)
0 to 1008
---
1
F616
0 (None)
B60B
...Repeated for module number 2
B676
...Repeated for module number 3
B6E1
...Repeated for module number 4
B74C
...Repeated for module number 5
B7B7
...Repeated for module number 6
B822
...Repeated for module number 7
B88D
...Repeated for module number 8
IEC 61850 Configurable GOOSE Reception (Read/Write Setting) (16 modules)
B900
Configurable GOOSE Dataset Items for Reception
(32 items)
0 to 197
---
1
F233
0 (None)
B920
...Repeated for module number 2
B940
...Repeated for module number 3
B960
...Repeated for module number 4
B980
...Repeated for module number 5
B9A0
...Repeated for module number 6
B9C0
...Repeated for module number 7
B9E0
...Repeated for module number 8
BA00
...Repeated for module number 9
BA20
...Repeated for module number 10
BA40
...Repeated for module number 11
BA60
...Repeated for module number 12
BA80
...Repeated for module number 13
BAA0
...Repeated for module number 14
BAC0
...Repeated for module number 15
BAE0
...Repeated for module number 16
Contact Inputs (Read/Write Setting) (96 modules)
BB00
Contact Input 1 Name
---
---
---
F205
“Cont Ip 1“
BB06
Contact Input 1 Events
0 to 1
---
1
F102
0 (Disabled)
BB07
Contact Input 1 Debounce Time
0 to 16
ms
0.5
F001
20
Table B–10: MODBUS MEMORY MAP (Sheet 45 of 60)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Summary of Contents for B30 UR Series
Page 10: ...x B30 Bus Differential System GE Multilin TABLE OF CONTENTS ...
Page 122: ...4 30 B30 Bus Differential System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Page 326: ...5 204 B30 Bus Differential System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 412: ...A 12 B30 Bus Differential System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Page 554: ...D 10 B30 Bus Differential System GE Multilin D 1 IEC 60870 5 104 APPENDIX D D ...
Page 566: ...E 12 B30 Bus Differential System GE Multilin E 2 DNP POINT LISTS APPENDIX E E ...
Page 574: ...F 8 B30 Bus Differential System GE Multilin F 3 WARRANTY APPENDIX F F ...