B.4 MEMORY MAPPING
APPENDIX B
B
4483
Ground CT 1 Secondary
0 to 1
---
1
F123
0 (1 A)
4484
...Repeated for CT Bank 2
4488
...Repeated for CT Bank 3
448C
...Repeated for CT Bank 4
4490
...Repeated for CT Bank 5
4494
...Repeated for CT Bank 6
VT Settings (Read/Write Setting) (6 modules)
4500
Phase VT 1 Connection
0 to 1
---
1
F100
0 (Wye)
4501
Phase VT 1 Secondary
25 to 240
V
0.1
F001
664
4502
Phase VT 1 Ratio
1 to 24000
:1
1
F060
1
4504
Auxiliary VT 1 Connection
0 to 6
---
1
F166
1 (Vag)
4505
Auxiliary VT 1 Secondary
25 to 240
V
0.1
F001
664
4506
Auxiliary VT 1 Ratio
1 to 24000
:1
1
F060
1
4508
...Repeated for VT Bank 2
4510
...Repeated for VT Bank 3
4518
...Repeated for VT Bank 4
4520
...Repeated for VT Bank 5
4528
...Repeated for VT Bank 6
Source Settings (Read/Write Setting) (6 modules)
4580
Source 1 Name
0 to 1
---
1
F206
“SRC 1"
4583
Source 1 Phase CT
0 to 63
---
1
F400
0
4584
Source 1 Ground CT
0 to 63
---
1
F400
0
4585
Source 1 Phase VT
0 to 63
---
1
F400
0
4586
Source 1 Auxiliary VT
0 to 63
---
1
F400
0
4587
...Repeated for Source 2
458E
...Repeated for Source 3
4595
...Repeated for Source 4
459C
...Repeated for Source 5
45A3
...Repeated for Source 6
Power System (Read/Write Setting)
4600
Nominal Frequency
25 to 60
Hz
1
F001
60
4601
Phase Rotation
0 to 1
---
1
F106
0 (ABC)
4602
Frequency and Phase Reference
0 to 5
---
1
F167
0 (SRC 1)
4603
Frequency Tracking Function
0 to 1
---
1
F102
1 (Enabled)
Breaker Control (Read/Write Settings) (6 modules)
47D0
Breaker 1 Function
0 to 1
---
1
F102
0 (Disabled)
47D1
Breaker 1 Name
---
---
---
F206
“Bkr 1"
47D4
Breaker 1 Mode
0 to 1
---
1
F157
0 (3-Pole)
47D5
Breaker 1 Open
0 to 4294967295
---
1
F300
0
47D7
Breaker 1 Close
0 to 4294967295
---
1
F300
0
47D9
Breaker 1 Phase A / Three-pole Closed
0 to 4294967295
---
1
F300
0
47DB
Breaker 1 Phase B Closed
0 to 4294967295
---
1
F300
0
47DD
Breaker 1 Phase C Closed
0 to 4294967295
---
1
F300
0
47DF
Breaker 1 External Alarm
0 to 4294967295
---
1
F300
0
47E1
Breaker 1 Alarm Delay
0 to 65.535
s
0.001
F003
0
47E3
Breaker 1 Pushbutton Control
0 to 1
---
1
F102
0 (Disabled)
47E4
Breaker 1 Manual Close Recall Time
0 to 65.535
s
0.001
F003
0
47E6
Breaker 1 Out of Service
0 to 4294967295
---
1
F300
0
47E8
Breaker 1 Block Open
0 to 4294967295
---
1
F300
0
Table B–10: MODBUS MEMORY MAP (Sheet 22 of 60)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Summary of Contents for B30 UR Series
Page 10: ...x B30 Bus Differential System GE Multilin TABLE OF CONTENTS ...
Page 122: ...4 30 B30 Bus Differential System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Page 326: ...5 204 B30 Bus Differential System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 412: ...A 12 B30 Bus Differential System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Page 554: ...D 10 B30 Bus Differential System GE Multilin D 1 IEC 60870 5 104 APPENDIX D D ...
Page 566: ...E 12 B30 Bus Differential System GE Multilin E 2 DNP POINT LISTS APPENDIX E E ...
Page 574: ...F 8 B30 Bus Differential System GE Multilin F 3 WARRANTY APPENDIX F F ...