869 MOTOR PROTECTION SYSTEM – COMMUNICATIONS GUIDE
MODBUS MEMORY MAP
CHAPTER 11: MODBUS MEMORY MAP
74113
0x8540
Change Inhibit 13
0
0xFFFFFFFF
1
FC142
0
1
74115
0x8542
Change Inhibit 14
0
0xFFFFFFFF
1
FC142
0
1
74117
0x8544
Change Inhibit 15
0
0xFFFFFFFF
1
FC142
0
1
74119
0x8546
Change Inhibit 16
0
0xFFFFFFFF
1
FC142
0
1
74121
0x8548
Events
0
1
1
FC126
1
1
Reduced Voltage Starting
74290
0x85F1
Function
0
4
1
FC100D 0
1
74291
0x85F2
Control Output Relays
0
0xFFFFFFFF
1
FC198E 0
1
74293
0x85F4
Transition Mode
0
2
1
FC373
0
1
74294
0x85F5
Start Level Current
25
300
1
x FLA
F2
125
1
74295
0x85F6
Start Timer
10
6000
1
s
F1
100
1
74296
0x85F7
Block
0
0xFFFFFFFF
1
FC142
0
1
74298
0x85F9
Trip Output Relays
0
0xFFFFFFFF
1
FC198D 0
1
74300
0x85FB
Events
0
1
1
FC126
1
1
74301
0x85FC
Targets
0
2
1
FC101
2
1
Breaker Control
74320
0x860F
Local Mode
0
0xFFFFFFFF
1
FC142
0
1
74323
0x8612
Local Open
0
3
1
FC322
1
1
74324
0x8613
Local Close
0
3
1
FC322
2
1
74325
0x8614
Remote Open
0
0xFFFFFFFF
1
FC142
0
1
74333
0x861C
Remote Close
0
0xFFFFFFFF
1
FC142
0
1
74342
0x8625
Events
0
1
1
FC126
1
1
74343
0x8626
Targets
0
2
1
FC101
1
1
Switching Device Control
74360
0x8637
Local Mode
0
0xFFFFFFFF
1
FC142
0
1
74362
0x8639
Local Stop
0
3
1
FC322
1
1
74363
0x863A
Local Start
0
3
1
FC322
2
1
74364
0x863B
Remote Stop
0
0xFFFFFFFF
1
FC142
0
1
74366
0x863D
Remote Start
0
0xFFFFFFFF
1
FC142
0
1
74368
0x863F
Events
0
1
1
FC126
1
1
74369
0x8640
Targets
0
2
1
FC101
1
1
Trip Bus 1
74380
0x864B
Name
0
65535
1
F60_26 Trip Bus 1
26
74393
0x8658
Function
0
4
1
FC100
0
1
74394
0x8659
Input 1
0
0xFFFFFFFF
1
FC142
0
1
74396
0x865B
Input 2
0
0xFFFFFFFF
1
FC142
0
1
74398
0x865D
Input 3
0
0xFFFFFFFF
1
FC142
0
1
74400
0x865F
Input 4
0
0xFFFFFFFF
1
FC142
0
1
74402
0x8661
Input 5
0
0xFFFFFFFF
1
FC142
0
1
74404
0x8663
Input 6
0
0xFFFFFFFF
1
FC142
0
1
74406
0x8665
Input 7
0
0xFFFFFFFF
1
FC142
0
1
74408
0x8667
Input 8
0
0xFFFFFFFF
1
FC142
0
1
74410
0x8669
Input 9
0
0xFFFFFFFF
1
FC142
0
1
74412
0x866B
Input 10
0
0xFFFFFFFF
1
FC142
0
1
74414
0x866D
Input 11
0
0xFFFFFFFF
1
FC142
0
1
74416
0x866F
Input 12
0
0xFFFFFFFF
1
FC142
0
1
Modbus
Address
Hex
Address
Description
Min
Max
Step Units
Format
Code
Factory
Default
Size in
Words