Chapter 6: Command Line Interface
158
GE-DS-82 and 82-PoE Ethernet Managed Switch User Manual
NOTE:
Change the VLAN mode for every time, user have to restart the switch for valid
value.
vlan mode
Description:
Add or edit VLAN entry.
Syntax:
vlan add <1-4094> NAME (cpu-port|no-cpu-port) LIST [LIST]
Parameters:
<1-4094>
specifies the VLAN id or Group id (if port based VLAN mode)
NAME
specifies the VLAN group name.
(cpu-port|no-cpu-port)
specifies the CPU port belong this VLAN group.
LIST
specifies the ports to be set to VLAN members.
[LIST]
specifies the ports to be set to tagged members. If not entered, all members set
to untagged.
e.g.. switch(config)# vlan add 1 vlan1 cpu-port 1-4
This VLAN entry has four members (from port1 to port4) and all members are
untagged.
no vlan
Description:
Delete VLAN entry.
Syntax:
no vlan <1-4094>
Parameters:
<1-4094>
specifies the VLAN id or group id (if port based VLAN).
e.g. no vlan 1
Summary of Contents for 82-POE
Page 26: ...Chapter 2 Installation 22 GE DS 82 and 82 PoE Ethernet Managed Switch User Manual ...
Page 148: ...Chapter 5 Console Management 144 GE DS 82 and 82 PoE Ethernet Managed Switch User Manual ...
Page 212: ...Chapter 6 Command Line Interface 208 GE DS 82 and 82 PoE Ethernet Managed Switch User Manual ...
Page 226: ......