SymSafe/SymSafe Pro
User Manual
56
Figure 35. The Alarms/Alarms Inputs and Outputs menu after camera selection
Table 24. The Alarms/Alarms Inputs and Outputs menu options
Menu Option
Setting
Input Mode
• Latched: The alarm is activated until it is silenced and acknowledged.
• Transparent: The alarm is active only while receiving alarm input
• Timeout: The alarm condition is latched for the amount of time
specified in the
Timeout
field.
Input type
Normally Open, Normally Closed
Timeout
0-59 minutes if Timeout selected in Input mode
Macro
None, Select Macro name (to select Macro Name you must have created
and named a macro in the
Schedule/Macros
menu
Protect
Enable or Disable
Buzzer
Enable or Disable
Enable or Disable
Alarm Out 1
Enable or Disable
Alarm Out 2
Enable or Disable
PTZ Presets
Enable, Address Presets, Presets 1-4 (launches the PTZ preset submenu
where you can assign an
Enable flag
,
Bus address, PTZ address,
and
Preset number.
Summary of Contents for SymSafe
Page 1: ...SymSafe SymSafe Pro User Manual ...
Page 10: ...SymSafe SymSafe Pro User Manual x ...
Page 28: ...SymSafe SymSafe Pro User Manual 18 Figure 6 Sample network diagram ...
Page 30: ...SymSafe SymSafe Pro User Manual 20 ...
Page 99: ...Chapter 5 SymNav and SymBrowser 89 Figure 63 The SymNav main operation screen ...
Page 116: ...SymSafe SymSafe Pro User Manual 106 Figure 82 The Alarms Inputs Outputs edit page ...
Page 133: ...Chapter 5 SymNav and SymBrowser 123 Network Figure 99 Network Info page ...
Page 135: ...Chapter 5 SymNav and SymBrowser 125 ...
Page 136: ...SymSafe SymSafe Pro User Manual 126 ...
Page 152: ...SymSafe User Manual 142 ...