Chapter 4
Programming
47
Siren options
provides siren option details.
Table 21. Siren options
Function
Default
Description
Piezo beeps
On
This option determines whether the panel piezo produces beeps based on system
activity (on) or is silent (off).
Panel voice
On
When On, arming level changes will be spoken.
Panel piezo
alarm
On
Determines whether the panel piezo emits alarm sounds (on) or not (off).
Trouble beeps
On
Determines whether the panel, X10, and hardwired interior sirens sound six beeps every
minute when a trouble condition occurs (on) or not (off). The following conditions cause
trouble beeps:
AC power failure (when AC power failure report is on) low CPU battery
Sensor failure (supervisory)
Sensor trouble (low battery, tamper, etc.)
Fail to communicate
Restoration of power
No Activity timer has timed out. Trouble beeps continue for 5 minutes and if the panel
does not see activity, trouble beeps stop and the panel reports the no activity to the
central station.
Trouble beeps can be silenced by arming or disarming the system or by pressing the
STATUS button. Trouble beeps resume 4 hours later if the trouble condition is not cleared.
Voice chime
Off
Determines whether the panel announces the sensor name.
1 = Sensor name
2 = Loud ding-dong bell
3 = Soft ding-dong bell
Off = No sound
Status beeps vol. 7
Determines the panel piezo volume level for status sounds such as arming, trouble, and
status beeps. Volume range is 1 (lowest) to 10 (highest).
HW siren sup.
Off
Determines whether the panel monitors hardwired sirens for open conditions (on) or not
(off). If this option is turned on, sirens connected to the panel terminals require an EOL
resistor in the wire circuit. (See
on page 17 for siren
wiring.) If this option is turned off, EOL resistors are not required whether sirens are
connected or not.
Speaker volume
8
Sets the volume of voice messages from the panel speaker. Volume range is 1 (lowest) to
8 (highest).
Silent police
panic
Off
Determines whether pressing the panel police panic button causes an audible (off) or
silent (on) alarm.
Panel tamper
alarm
Off
Determines whether the panel activates a tamper alarm anytime the cover is opened
(On) or only when the system is armed (Off).
Alarm report
verify
Off
This option determines whether the panel verifies successful alarm reports to the central
station by displaying
Phone comm is OK
(On), or not (Off).