Chapter 2
Planning
15
Speaker volume
8
8
1 to 8
D, I, M
Panel silent police panic
Off
Off
On (silent), Off (audible)
D, I
Panel tamper alarm
Off
Off
On/Off
D, I
Alarm report verification
Off
Off
On/Off
D, I
Audio verify menu
Audio mode
Off
Off
Off - Audio mode disabled
1 - Instant mode
2 - Callback mode
D, I
Fire shutdown
Off
Off
On/Off
D, I
Panic talk
Off
Off
On/Off
D, I
Vox receiver gain
6
6
1 to 32
D, I
Vox mic gain
24
24
1 to 64
D, I
Vox mic gain range
64
64
1 to 64
D, I
Manual mic gain
64
64
1 to 64
D, I
Light control menu
Set entry lights
Off
Off
On/Off for each unit number
from 1 to 8
D, I, M
Sensor light
Off
Off
1 to 8, Off
D, I, M
Light schedule
None
None
HH:MMx for start and stop
times, None
D, I, M
Housecode
A
A
A to O
D, I, M
Lock interval
None
None
HH:MMx for start and stop
times, None
D, I, M
System test menu
Sensor test
D, I, M
Communication test
D, I, M
System download
D, I, M
a.
This column tells what type of access code is allowed to make changes: D = dealer code, I = installer code, M = master code.
Table 6.
System programming menu options (continued)
Function
Default
Delete
Range
Access
code
a
Installer