Simon XT
Installation Manual
60
Central station communication
After performing sensor and communication tests, check that the system is reporting alarms successfully to the
central station.
provides a list of sensor/user report codes.
To test communication with the central station:
1. Call the central station and tell the operator that you will be testing the system.
2. Arm the system.
3. Test each of the wireless panic buttons and trip at least one sensor of each type (fire, intrusion, etc.) to
verify that the appropriate alarms are working correctly.
4. When you finish testing the system, call the central station to verify that the alarms were received.
Table 31. Sensor/user report codes
Arm or disarm from
Reports as user
Panel or remote handheld touchpad
0
Keyfob
1 to 40 (sensor number)
Panel aux panic
41
Panel tamper
42
Panel police panic
43
Panel fire panic
44
Dealer access code
44
Installer access code
45
Master code
46
Access codes 1 to 8
47 to 54
Duress code
55