SETPOINTS MODE
5-1
All the messages displayed by the 565 Relay in the setpoints
mode are shown and explained in this section. As for actual
values, the messages are laid out in book form with a number
of pages. Each page contains lines displaying a message.
The setpoints section has several pages, the contents of
which are as follows:
Page Contents
1.
User Level setpoints.
2.
Phase Current setpoints.
3.
Ground Current setpoints.
4.
Configuration setpoints.
5.
Analog Input setpoints.
6.
Analog Output setpoints.
7.
Communications setpoints.
8.
Calibration Mode setpoints.
9.
Voltage setpoints.
10.
Demand Metering setpoints.
11.
MTM Metering setpoints.
The numbers in the “Location” column to the left of each
message in this section give the page and line of that
message in the 565 Relay’s memory. For example, the
message to the right of the number S 1.2 in the “Location”
column will appear on page 1 and line 2 when the Relay is in
setpoints mode. The “Message Line” column shows the
actual message which can be read from the LCD display on
the front panel of the unit. The 565 Relay has two user levels,
“basic” and “advanced”. The messages seen depend on this
user level, which is chosen in page one of setpoints. The
basic level allows the user to operate the relay using the
minimum of the features necessary. The advanced level
allows the user to use all the 565 Relay features.
The messages which will only be seen by the advanced user
and not the basic user, are marked “
L
A
”, for “Level-ad-
vanced” in the Location column.
Quantities shown in display boxes are typical values only.
Different quantities will be displayed in each particular appli-
cation.
Relay Selection
The 565/575 Relay has six internal relays. They are called
Trip, Close, Aux. 1, 2, 3, and 4. The following are the combi-
nations of relays which you can select to have activated by
any alarm or trip condition. This selection must be made in
the setpoints mode.
ALARM RELAY
TRIP RELAY
SELECTION
SELECTION
1. Aux 1
1. Trip
2. Aux 2
2. Aux 1 (565 only)
3. Aux 1&2 (565 only)
3. Aux 2 (565 only)
4. Trip & Aux 1
5. Trip & Aux 2 (565 only)
6. Aux 1&2
7. Trip & Aux 1&2
The relay(s) to be activated can be displayed by pressing the
NEXT CHOICE key. The display will show one of the options
above, each time the key is pressed. When the last item is
reached, the display will go back to the first item the next time
the NEXT CHOICE key is pressed.
For example, say a combination of relays is being assigned
to the undervoltage trip condition in setpoints. If the Trip relay
and Auxiliary 1 relay need to be activated by this condition,
the NEXT CHOICE key is pressed until the display shows
UNDERVOLT TRIP
RELAY TRIP&AUX1
The STORE key is then pressed to store the selected relay or
combination of relays in the 565/575 Relay’s memory. The
following message will appear for two seconds to verify that
this has been done.
NEW SETPOINT
STORED
When more than one relay is selected as shown, all the
selected relays will be energized simultaneously. The con-
tacts of the selected relay(s) can then be used to provide
remote alarms or trips. These contacts are available at the
rear of the 565 Relay panel. See the wiring diagram for
terminal numbers.
Setpoint Message Abbreviations
The following abbreviations are used in the messages in the
setpoints pages:
A
Ampere
AL’M
Alarm
AUX
Auxiliary
COMM
Communications
CT
Current Transformer
CURR
Current
CYC
Cycles
DISCREP.
Discrepancy
EXTREM
Extremely
FREQ
Frequency
GND
Ground
Hz
Hertz
INST
Instantaneous
INV
Inverse
KA
Kiloamps
KV
Kilovolts
KVAR
Kilovars
KW
Kilowatts
LCD
Liquid Crystal Display
mA
Milliamps
Summary of Contents for 565
Page 6: ...INSTALLATION 2 2 Figure 2 1 Mounting Details ...
Page 7: ...INSTALLATION 2 3 Figure 2 2 Mounting Arrangement with Relay Collar ...
Page 12: ...INSTALLATION 2 8 Figure 2 5 565 Relay Typical Wiring ...
Page 13: ...INSTALLATION 2 9 Figure 2 6 Voltage Sensing Wire ...
Page 14: ...INSTALLATION 2 10 Figure 2 7A 565 with MTM CT and Open Delta VT Typical Wiring ...
Page 15: ...INSTALLATION 2 11 Figure 2 7B 565 with MTM CT and Wye VT Typical Wiring ...
Page 16: ...INSTALLATION 2 12 Figure 2 8A Open Delta VT and CT MTM Typical Wiring ...
Page 17: ...INSTALLATION 2 13 Figure 2 8B Wye VT and CT MTM Typical Wiring ...
Page 18: ...INSTALLATION 2 14 Figure 2 9 MTM Mounting Dimensions ...
Page 19: ...INSTALLATION 2 15 Figure 2 10 565 Rear Panel Layout ...
Page 20: ......
Page 23: ...DISPLAY AND KEYBOARD 3 3 Figure 4 1 565 Relay Front Panel ...
Page 28: ......
Page 132: ......
Page 142: ...CURVE INFORMATION ANDTABLES 7 10 Figure 7 9 IEC A Curves ...
Page 143: ...CURVE INFORMATION ANDTABLES 7 11 Figure 7 10 IEC B Curves ...
Page 144: ...CURVE INFORMATION ANDTABLES 7 12 Figure 7 11 IEC C Curves ...
Page 176: ...RELAYTESTING 8 2 Figure 8 1 Secondary Injection Test Setup ...
Page 180: ......
Page 184: ......
Page 192: ...APPENDIX C C 2 Figure C1 System Controller Block Diagram 1 2 ...
Page 193: ...APPENDIX C C 3 Figure C2 System Controller Block Diagram 2 2 ...
Page 194: ......
Page 198: ......