background image

22

BE24G

IT

Dichiarazione di conformità UE

Il fabbricante:                

GI.BI.DI. 

Via Abetone Brennero, 177/B,

46025 Poggio Rusco (MN) ITALY

dichiara che il prodotto:

APPARECCHIATURA ELETTRONICA BE24

sono conformi alle seguenti Direttive:

• 

e che sono state applicate le seguenti norme armonizzate:

Data 

                                    

S.r.l.

Direttiva 2014/35/UE  e successive modifiche

;

• 

Direttiva 2014/30/UE  e successive modifiche

;

Direttiva 2014/53/UE  e successive modifiche

;

• 

Direttiva 2011/65/UE  e successive modifiche

;

• 

• 

• 

• 

• 

• 

• 

• 

• 

• 

08/02/2019

EN 301 489-1 V2.2.0;

EN 301 489-3 V2.1.1;
EN 300 220-2 V3.2.1;
EN 62479:2010;
EN 60950-1:2014;

IEC 61000-6-1:2016 RVL
IEC 61000-6-2:2016 RVL
IEC 61000-6-3:2020
IEC 60335-2-103:2015+AMD1:2017+AMD2:2019 CSV

Il Rappresentante Legale

Michele Prandi

23

UK

BE24G

• Red warning LEDs for N.C. contacts and for programming.
• Blue LED for times programming.
• Buttons on the circuit board for programming and learning the radio controls.
• Automatic run time learning with simplified procedure.
• Onboard radio receiver that can store up to 200 radio controls.
• Control of the radio transmitter channels via dip switches.
• Deceleration during opening and closing.
• Deceleration speed adjustable via DIP switch.
• Stop and motion inversion after intervention of the safety devices.
• Anti-crushing function both at normal speed and in deceleration.
• Amperometric reading of motor absorption for the anti-crushing function adjustable via DIP switch.
• Pedestrian operation with motor 1 opening.
• Two N.C. inputs,  photocell 1, photocell 2.
• One input (SAFETY) programmable as STOP or EDGE.
• Two possible operating logics: step-by-step with stop or condominium selectable via DIP switch.
• Gate phase shift time adjustable via DIP switch.
• Enabling and differentiate programming of the total and pedestrian automatic reclosure.
• Provision for use with buffer batteries.
• Soft-Start and Soft-Stop to limit mechanical shock.

2 - TECHNICAL SPECIFICATIONS/FUNCTIONS

1 - TECHNICAL SPECIFICATIONS

BE24G / AS06270

230 VAC single-phase 50/60 Hz

1-2

24 Vdc

24 Vdc 10W max

Integrated, 200 trasmitters maximum

-20°C +60°C 

ENCODER or TIME

24 Vdc 10W max

Electronic control unit for automation 

of a double swing gate with 24VDC motors

Control unit

Power supply

No. of motors

Motor power supply

Flashlight

Radio receiver

Operating temperature

Run time

Accessory power supply

Type

WARNINGS:

This product has been tested by GI.BI.DI. for full compliance with the requirements of the directives in force. GI.BI.DI. S.r.l. reserves 
the right to change the technical data without prior notice in relation to product development.

READ CAREFULLY THESE INSTRUCTIONS BEFORE PROCEEDING WITH INSTALLATION.

Thank you for choosing GIBIDI.

DISPOSAL: 

GI.BI.DI. advises recycling the plastic components and to dispose of them at special authorised 

centres for electronic components thus protecting the environment from polluting substances.

Summary of Contents for BE24G

Page 1: ...24G AS06270 Apparecchiatura elettronica ISTRUZIONI PER L INSTALLAZIONE Electronic control unit INSTRUCTIONS FOR INSTALLATION Platine lectronique INSTRUCTIONS POUR L INSTALLATION Elektronische apparatu...

Page 2: ...OM COM 5Vdc S2 S1 ENCODER M1 ENCODER M2 5Vdc COM PHOTO1 NC START NO PED NO PHOTO2 NC COM STOP SAF NC IN1 IN2 EL EL LAMP LAMP 24Vdc 10W MAX ACC ACC 24Vdc 0Vdc M1 M2 M3 M4 M5 M6 CF2 CF1 F1 F2 F3 P1 P2 D...

Page 3: ...M3 CAVO MARRONE BROWN WIRE CAVO BLU BLUE WIRE CAVO MARRONE BROWN WIRE CAVO BIANCO WHITE WIRE CAVO VERDE GREEN WIRE Motore 2 Motor 2 CAVO BLU BLUE WIRE CAVO MARRONE BROWN WIRE CAVO BIANCO WHITE WIRE CA...

Page 4: ...L LOCK CONNECTION 4 4 COLLEGAMENTO LAMPEGGIANTE FLASHING LIGHT CONNECTION M2 ON 6 OFF DIP2_6 ON on off on off on off ON 6 OFF DIP2_6 OFF on off on off on off 24Vdc MAX 10W 4A M2 24Vdc MAX 10W COLLEGAM...

Page 5: ...VI DI COMANDO CONTROL DEVICES CONNECTION COM START NO PED NO M4 6A COLLEGAMENTO OROLOGIO EXTERNAL CLOCK CONNECTION COM IN1 NO M4 COLLEGAMENTO SPIRA MAGNETICA ELECTROMAGNETIC DETECTOR CONNECTION MMD CO...

Page 6: ...RX DGF100 200 COLLEGAMENTO FOTOCELLULE 2 PHOTOCELLS 2 CONNECTION 2 3 RX TX M1 1 2 3 4 M2 1 2 3 RX TX M1 1 2 3 4 M2 1 4 M2 M4 ACC ACC PHOTO2 NC COM 1 2 TX 1 3 4 5 2 RX 1 2 TX 1 3 4 5 2 RX 4 M2 M4 ACC A...

Page 7: ...2 ON 4 OFF DIP1_2 OFF SW2 NC ON 4 OFF DIP1_2 OFF SW2 M4 M4 4 COM COM STOP SAF 8K2 COLLEGAMENTO DISPOSITIVO DI SICUREZZA NC NC SAFETY DEVICE CONNECTION NC NC NC ON 4 OFF DIP1_2 ON SW2 M4 4 31 12 8K2 CO...

Page 8: ...NTOLUNGO LONGSLOWDOWNTRAVEL IMPOSTAZIONE DI DEFAULT DIP1 DIP1 DEFAULT SETTINGS PRELAMPEGGIODISABILITATO PREFLASHINGDISABLED PRELAMPEGGIOABILITATO PREFLASHINGENABLED TAMPOSFASAMENTOANTE LEAFSPHASESHIFT...

Page 9: ...GS 4 19 PED PED PED PED 3 4 3 4 3 4 3 4 IMPOSTAZIONE DI DEFAULT DIP3 DIP3 DEFAULT SETTINGS 4 17 1 2 3 4 5 6 ASSEGNAZIONECOMANDODISTARTATASTOTRASMITTITORE STARTCOMMANDTOTRANSMITTERBUTTONALLOCATION ASSE...

Page 10: ...2 10 BE24G KIT BATTERIE DI BACKUP ESTERNO EXTERNAL BACKUP KIT BATTERY AJ01483 4 20 M6 CF2 CF1 F1 F2 BE24...

Page 11: ...Tempo sfasamento ante regolabile tramite dip switch Abilitazione e programmazione differenziata della richiusura automatica totale e pedonale Predisposizione per uso con batterie tampone Soft Start e...

Page 12: ...istruzioni si rivolge a persone abilitate all installazione di apparecchi sotto tensione pertanto si richiede una buona conoscenza della tecnica esercitata come professione e nel rispetto delle norme...

Page 13: ...ene intercettata durante la chiusura inverte immediatamente il moto in apertura Inapertura ininfluente Inpausaricaricailtempodipausa Senonutilizzatoponticellareconmorsetton 22 IngressoFOTOCELLULA2 N C...

Page 14: ...l contatto del morsetto PHOTO2 L5 ROSSO SAFETY Sempre acceso si spegne quando viene rilevato un valore non corretto sul morsetto SAFETY L7 ROSSO RX SEMPRE spento Si accende quando viene premuto il pul...

Page 15: ...celloaperto STOP norichiusuraautomatica Durantelachiusura STOP Dopouno STOP Inverteilmoto ININFLUENTE Funzionamento Cancello chiuso ININFLUENTE Durante l apertura Inversione immediata del moto per 1s...

Page 16: ...ionamento al comando di START si avr in sequenza attivazione dell elettroserratura impulso in chiusura di 1 s apertura dopo 2 s sgancio dell elettroserratura ON OFF 10 DIP SWITCH DIP2 Le impostazioni...

Page 17: ...LAMPEGGIATORE acceso lampeggiante con i motori attivi IT APPRENDIMENTO TEMPO DI PAUSA Abilita la funzione colpo finale in chiusura Funzionamento Dopo il rallentamento il moto prosegue per 1s per facil...

Page 18: ...PED ON ON Ingresso associato al pulsante 4 del trasmettitore PED Se l impostazione uguale a DIP3_1 e DIP3_2 il PEDONALE disabilitato 3_5 OFF INUTILIZZATO 3_6 ON OFF INUTILIZZATO Tenere OFF non modific...

Page 19: ...na qualsiasi sicurezza invertire i cavi del motore e ripetere la procedura Movimenti eseguiti durante l apprendimento con 2 motori Motore 1 apre fino ad incontrare le battute meccaniche Motore 2 apre...

Page 20: ..._7 ON Il LAMPEGGIANTE si accende fisso Premere PED per iniziare il conteggio del tempo di pausa Il LAMPEGGIANTE emette brevi lampeggi a cadenza di 1 secondo Trascorso il tempo di pausa desiderato MAX1...

Page 21: ...e il led L8 lam La portata del trasmettitore molto bassa Verificare che i morsetti 26 e 27 siano ben stretti Controllare e o sostituire la batteria del trasmettitore Il cancello non apre chiude comple...

Page 22: ...te le seguenti norme armonizzate Data S r l Direttiva2014 35 UE esuccessivemodifiche Direttiva2014 30 UE esuccessivemodifiche Direttiva2014 53 UE esuccessivemodifiche Direttiva2011 65 UE esuccessivemo...

Page 23: ...h Enabling and differentiate programming of the total and pedestrian automatic reclosure Provision for use with buffer batteries Soft Start and Soft Stop to limit mechanical shock 2 TECHNICAL SPECIFIC...

Page 24: ...ces that share the same N O normally open input Incorrect installation or improper use of the product may compromise system safety Keep all the materials contained in the packaging away from children...

Page 25: ...ingclosing It stops and inverts the motion opening the gate completely If the gate is closed it does notaffectitsfunctioning Ifinterceptedduringpause itreloadsthepausetime Ifnotused makeajumperwithter...

Page 26: ...hen the resistance value of terminal SAFETY is wrong L6 RED IN1 Lights when the contact switch from open to close and remain on until the contact switch off The control board is locked it s necessary...

Page 27: ...re disabled OFF ON Enable the automatic closure or after the pause time set by default 10s or after the pause time learned ON OperationinresponsetotheSTARTcommand Gateclosed OPENS Duringopening STOPS...

Page 28: ...will occur in sequence electric lock activation closing pulse of 1 sec opening electric lock release after 2 sec ON OFF 10 DIP SWITCH DIP2 Decelerationspeedequalto50 ofthemaximumspeed 2_1 Deceleration...

Page 29: ...ng cycle will be required changing this setting will resetthecontrolboardanda new learning cycle will be required 2_5 Disables the final stroke in closing function ON UNUSED OFF 2_6 ON OFF 2_7 ON ON O...

Page 30: ...in the boxes with grey background Transmitter button 1 Transmitter button 2 Transmitter button 3 Transmitter button 4 13 ONBOARD RADIO RECEIVER CONTROL Storing a new transmitter in memory 1 Press and...

Page 31: ...DIP 2_7 is in OFF Press and release P1 button Led L8 will come on after 30 seconds of no user interaction the control board will quit learning procedure Within 30 seconds press button 1 of the radio c...

Page 32: ...utomatic reclosing time 20 s Pedestrian automatic reclosing time 10 s Be sure that the control unit has already successfully stored a stroke learning Be sure that the gate has finished the closing man...

Page 33: ...t learningproceduremustbeexecuted Transmitter range is short Check terminals 26 27 screws are tight Check and replace transmitter battery The gate does not fully open close Check the motor and encoder...

Page 34: ...ntial requirements and other relevant requirement of Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012 Electrical Equipment Safety Regulati...

Page 35: ...dip switch Arr t et inversion du mouvement apr s l intervention des dispositifs de s curit Fonction anti crasement tant vitesse normale qu vitesse ralentie Lecture amp re m trique de l absorption du m...

Page 36: ...vaise installation ou une mauvaise utilisation du produit peut compromettre la s curit de l installation Tous les mat riaux pr sents dans l emballage ne doivent pas tre laiss s la port e des enfants c...

Page 37: ...erture elle n est pas influente En pause elle recharge le temps de pause Sipasutilis faireunpontavecbornen 22 M2 Entr e PHOTOCELLULE 2 N C active en ouverture et fermeture Quandelleest intercept e ell...

Page 38: ...act du borne PHOTO2 L5 ROUGE SAFETY Toujours allum s teint quand on rel ve une valeur pas correct sur la borne SAFETY 2A T F4 Protection transformateur L7 ROUGE RX TOUJOURS teint S allume quand on app...

Page 39: ...pasderefermetureautomatique Pendantlafermeture STOP Apr sunSTOP inverselemouvement PASINFLUENT Fonctionnement Portail ferm PAS INFLUENT Pendant l ouverture Inversion imm diate du mouvement par 1s ral...

Page 40: ...la commande de START il y aura en s quence activation de la serrure lectrique impulsion en fermeture de 1 s ouverture apr s 2 s d crochage de la serrure lectrique ON OFF 10 DIP SWITCH DIP2 Les positio...

Page 41: ...n met z ro la centrale et il est n cessaire faire un nouveau cycled apprentissage 2_5 D sactive la fonction coup final en fermeture ON PAS UTILISE OFF 2_6 ON OFF 2_7 ON ON OFF LAMPE TEMOIN CLIGNOTEUR...

Page 42: ...PED ON ON Entr e associ e la touche 4 de l metteur PED Si la position est gale DIP3_1 et DIP3_2 le PIETONestd sactiv 3_5 OFF PAS UTILISE 3_6 ON OFF PAS UTILISE Tenir OFF ne pas modifier 13 GESTION RE...

Page 43: ...e DIP 2_7 soit en OFF Appuyer sur la touche P1 Le led L8 s allumera et restera allum par 30 s en suite la centrale sortira de la fonction auto apprentissage Dans 30 s led L8 allum appuyer sur la touch...

Page 44: ...e fixe Appuyer sur PED pour commencer le comptage du temps de pause Le FEU CLIGNOTANT clignote rapidement chaque seconde Apr s le temps de pause choisi MAX127 s donner une nouvelle commande de PED Le...

Page 45: ...ait La port e de l metteur est tr s basse V rifier que les bornes 26 et 27 soient bien serr s Contr ler et ou remplacer la batterie de l metteur Le portail n ouvre ferme pas compl tement V rifier les...

Page 46: ...B 46025 Poggio Rusco MN ITALY d BE24 Date S r l Directive2014 35 UEetmodificationssuccessives Directive2014 30 UEetmodificationssuccessives Directive2014 35 UEetmodificationssuccessives Directive2014...

Page 47: ...differentieerde activering en programmering van automatische totaal en voetgangersversluiting Voorziening voor gebruik met buffer batterijen Soft Start en Soft Stop om de mechanische schokken te beper...

Page 48: ...veiligheidsstrip Differentieer en houd de vermogenskabels met minimum doorsnede Voer de verschillende aansluitingen uit en raadpleeg hiervoor de volgende tabellen en de bijgevoegde zeefdruk Let er in...

Page 49: ...keert om door compleet te openen Heeft bij gesloten hek geen invloed Indien geactiveerd tijdens de pauzetijd wordt de pauzetijd verhoogd Indien nietgebruikt maakeenbrugmetklemnr 22 M2 IngangFOTOCEL2...

Page 50: ...de FOTOCEL2 wordt geopend 2A T F4 Beveiliging van de transformator L5 ROOD SAFETY Brandt altijd Gaat uit wanneer de weerstandwaarde van de klem VEILIGHEID verkeerd is De elektronische besturing is ve...

Page 51: ...ngvoor1sec bijlagesnelheid Poortisgeopend NIETVANINVLOED Tijdenshetsluiten Onmiddellijkomkeringvandebewegingvoor1sec bijlagesnelheid Poort is gesloten NIET VAN INVLOED 1_1 1_2 1_3 1_4 GEVOELIGHEID INK...

Page 52: ...gingssnelheidisgelijkaan50 vandemaximumsnelheid 2_1 Vertragingssnelheidisgelijkaan30 vandemaximumsnelheid ON VERTRAGINGS SNELHEID OFF Snelheidbijeennormalebeweginggelijkaan100 vandemaximumsnelheid 2_2...

Page 53: ...al de besturingseenheid resetten en een nieuwe leercycli moet uitgevoerd worden wijzigen van deze instelling zal de besturingseenheid resetten en een nieuwe leercycli moet uitgevoerd worden 2_5 Dit sc...

Page 54: ...der knop 1 Zender knop 2 Zender knop 3 Zender knop 4 13 AANLEREN VAN DE AFSTANDBEDIENINGEN Programmeren van een nieuwe afstandbediening in het geheugen 1 Druk op de P2 knop en laat los 2 Led L6 gaat b...

Page 55: ...nwezig zijn op de grond of op de motor Verwijder alle hindernissen in het bereik van de beweging van het automatiseringssysteem Controleer of dat de leds L3 L4 L5 en L9 branden Controleer of DIP 2_7 o...

Page 56: ...straalt korte flitsen uit met tussenpozen van 1 seconde Geef na de gewenste pauzetijd MAX 127 seconden een nieuw PED commando Het KNIPPERLICHT gaat continu branden om het succes van de bewerking aan...

Page 57: ...van de afstandbediening is kort Controleer de klemmen 26 27 dat de schroeven goed aangedraaid zijn Controleer en vervang de batterij van de afstandbediening De poort opent sluit niet volledig Control...

Page 58: ...025 Poggio Rusco MN ITALY R Datum S r l ichtlijn2014 35 UEendaaropvolgendewijzigingen Richtlijn2014 30 UEendaaropvolgendewijzigingen ichtlijn2014 53 UEendaaropvolgendewijzigingen Richtlijn2011 65 UEen...

Page 59: ...59 BE24G NOTES...

Page 60: ...DI S r l Via Abetone Brennero 177 B 46025 Poggio Rusco MN ITALY Tel 39 0386 52 20 11 Fax 39 0386 52 20 31 E mail info gibidi com Numero Verde 800 290156 w w w g i b i d i c o m Cod AIC8400 06 2023 Re...

Reviews: