28
BE24G
UK
9 - DIP SWITCH DIP1
The settings are stored during the rest phase (gate closed).
The default settings are highlighted in the boxes with grey background.
1_7
Enables pre-flashing of 3 seconds before motor activation during opening and closing.
Disables gate phase shift time.
ON
OFF
PRE-FLASHING
1_8
1_9
GATE PHASE
SHIFT TIME
Motor 2 delay during opening: 3 seconds.
Motor 1 delay during closing: 3 seconds.
OFF
OFF
OFF
ON
ON
OFF
ON
ON
Disables pre-flashing.
Motor 2 delay during opening: 3 seconds.
Motor 1 delay during closing: 6 seconds.
Motor 2 delay during opening: 3 seconds.
Motor 1 delay during closing: 9 seconds.
1_10
WATER HAMMER
Disables the water hammer function.
Enables the water hammer function during opening to help electric lock release.
Operation:
at the START command, the following will occur in sequence:
- electric lock activation;
- closing pulse of
1 sec
;
- opening;
- electric lock release after
2 sec
.
ON
OFF
10 - DIP SWITCH DIP2
Deceleration speed equal to 50% of the maximum speed.
2_1
Deceleration speed equal to 30% of the maximum speed.
ON
DECELERATION
SPEED
OFF
Speed during normal movement equal to 100% of the maximum speed.
2_2
Speed during normal movement equal to 80% of the maximum speed.
ON
MOVEMENT SPEED
OFF
Enables fast closing function.
Operation: Reduces the stand-by time to 3 seconds following interception and
subsequent freeing of the photocells. Active only on photocell 1.
2_3
Fast closing disabled.
ON
FAST CLOSING
OFF
The settings are stored during the rest phase (gate closed).
The default settings are highlighted in the boxes with grey background.
Description
DIP
Status
Function
Description
DIP
Status
Function
changing this setting will
reset the control board
and a new learning cycle
will be required.
changing this setting will
reset the control board
and a new learning cycle
will be required.
29
BE24G
UK
10 - DIP SWITCH DIP2
The settings are stored during the rest phase (gate closed).
The default settings are highlighted in the boxes with grey background.
Description
JUMPER
Status
Function
SW2
FUNCTIONING
TERMINAL 21
N.C. devices are connected to STOP/EDGE (21) input
8,2KOhm (8K2) resistive devices are connected to STOP/EDGE (21) input.
The settings are stored during the rest phase (gate closed).
The default settings are highlighted in the boxes with grey background.
11 - JUMPER SW2
Long deceleration (~33% of the total stroke).
Irrelevant if DIP2_4=OFF
2_4
2_9
Short deceleration (~25% of the total stroke)
ON
ON
FUNCTIONING
DECELERATION
DISTANCE
OFF
OFF
Description
DIP
Status
Function
changing this setting will
reset the control board and a
new learning cycle will be
required.
changing this setting will
reset the control board and a
new learning cycle will be
required.
2_5
Disables the final stroke in closing function
ON
UNUSED
OFF
2_6
ON
OFF
2_7
ON
ON
OFF
WARNING LIGHT
/
FLASHING LIGHT
FINAL STROKE
IN CLOSING
2_8
Terminal M2_7 and M2_8 work as WARNING LIGHT
Terminal M2_7 and M2_8 work as FLASHING LIGHT
PAUSE TIME
LEARNING
Enables the final stroke in closing function.
Operation:
After slowing down, the movement continues in slow down mode for 1s to facilitate
the locking of the electric lock.
During the final stroke in closing the safety devices and the commands are not
active (PHOTO, EDGE, START, etc.)
OFF
Enabling of an additional deceleration ramp at the end of the motion next to the
mechanical limit switch in opening or closing.
Not enabled if it is time operation (DIP2_4=OFF)
2_10
Disables the Soft Stop function
ON
SOFT STOP
OFF
TIME
ENCODER
PAUSE TIME LEARNING ENABLED
STANDARD OPERATION
Summary of Contents for BE24G
Page 59: ...59 BE24G NOTES...