GBC StreamPunch Ultra/Ultra MP
11-05-2018
RTPS
2-18
RTP 1.2 No DC Power
Use this RTP when there is no
i
ndication of 24 VDC power.
1. Do ARP 1.6 to remove the Rear Cover.
2. Plug in the AC power cord and turn ON the AC power switch.
WARNING
Moving Parts, keep hands clear of nips and the belts when the
Interlock Cheater is inserted.
3. Check the LEDs on the Control Board.
•
With the front door closed there will be (4) LEDs that will be lit.
•
With the front door open, there will be (3) LEDs that will be lit.
The LEDs are lit.
Yes
- Go to step 9
No
- Go to step 4.
4. Check for line voltage on Wire 7715493 at Connector J3 on the Main
Control Board (Section 7 Wiring).
There is line voltage.
Yes
- Go to Step 5
No
- Do RTP 1.1 No AC Power.
5. Check the following connections:
•
Connection of cable 7715492 at J1 at the Main Control Board.
•
Connection of cable 7715493 at J3 at the Main Control Board.
Connections are good.
Yes
- Go to Step 6
No
-
Make the connections then return to normal operation.
6. Do ARP 4.1 to remove 24 VDC Power Supply.
7. With the power supply outside the machine, make the connections at
J1 and J3 and the ground cable.
WARNING
Do not touch the open terminals of the power supply or any
other connector with the AC power cord connected. The
machine components contain dangerous electrical voltages that
can result in electrical shock and possible serious injury.
8. Check if the LED in the power supply is lit.
LED is lit
Yes
- Go to Step 10
No
- Go to Step 9
9. Replace Cable 7715493
This clears the fault.
Yes
- Return to normal operation
No
- Replace the 24V DC power supply (PL 4.1)
10. Check if there is no 24V power to any other components like a
Solenoid, or a Stepper Motor,
There is no 24V power to any other components
Yes
- Replace the Main Control Board (PL 6.1)
No
- Go to Step 11
11. Check for 24 VDC on Cable 7715492 at Connector J1 on the Control
Board.
•
Pin 1 = ORG Wire
•
Pin 2 = ORG Wire
•
Pin 3 = ORG Wire
•
Pin 6 = BLK Wire
•
Pin 7 = BLK Wire
•
Pin 8 = BLK Wire
There is 24 VDC at Connector J1 on the Control Board
Yes
- Go to Step 12
No
- Replace Cable 7715492
.
12. Determine if you have been directed here from another RTP because
there is no 24 VDC power output from the Control Board to another
component.
There is no 24 VDC power output from the Control Board to
another component.
Yes
- Replace the Main control board (PL 6.1)
No
- Normal operation
Summary of Contents for StreamPunch Ultra
Page 2: ...Service Manual 11 05 2018 GBC StreamPunch Ultra Ultra MP ii ...
Page 9: ...GBC StreamPunch Ultra Ultra MP 11 05 2018 Service Manual ix Notes ...
Page 17: ...Service Call Procedures 02 03 2017 GBC StreamPunch Ultra Ultra MP 1 8 Notes ...
Page 66: ...GBC StreamPunch Ultra Ultra MP 11 05 2018 RTPS 2 49 Notes ...
Page 231: ...GBC StreamPunch Ultra Ultra MP 02 03 2017 Adjustments Repairs 4 151 Notes ...
Page 354: ...General Procedures and Information 11 05 2018 GBC StreamPunch Ultra Ultra MP 6 80 Notes ...
Page 356: ...Wiring Data 05 10 2018 GBC StreamPunch Ultra Ultra MP 7 2 This page intentionally left blank ...
Page 359: ...GBC StreamPunch Ultra Ultra MP 05 10 2018 Wiring Data 7 5 Plug Jack connectors ...
Page 369: ...Installation Instructions 02 03 2017 GBC StreamPunch Ultra Ultra MP 8 10 Notes ...