General Procedures and Information
11-05-2018
GBC StreamPunch Ultra/Ultra MP
6-48
Die Set Inspection
1. Set the Die Set on a table and press the top plate straight down at
both ends at the same time and look for a smooth operation. The top
plate and pins should retract fully when you release.
Check For Free Movement
2. Reinstall the Die Set into the punch and run several sheets of the
customer’s paper through the punch. Inspect the holes.
•
Holes should be clean and even with no tearing or frayed edges.
•
Holes should be punched completely, leaving no chip attached.
•
Holes should be straight (no skew) and evenly spaced from the
edge of the paper and aligned. (See GP 6.2.9, SKEW OFFSETS
).
GP 6.7.4 Die Set Shoulder Bolts
Do the following to inspect and lubricate the Die Set Shoulder Bolts every
200k Die cycles.
1. Lubricate with high quality Teflon-based grease.
2. Apply grease to Shoulder Bolts and Springs [2].
3. Wipe up any excess grease.
Summary of Contents for StreamPunch Ultra
Page 2: ...Service Manual 11 05 2018 GBC StreamPunch Ultra Ultra MP ii ...
Page 9: ...GBC StreamPunch Ultra Ultra MP 11 05 2018 Service Manual ix Notes ...
Page 17: ...Service Call Procedures 02 03 2017 GBC StreamPunch Ultra Ultra MP 1 8 Notes ...
Page 66: ...GBC StreamPunch Ultra Ultra MP 11 05 2018 RTPS 2 49 Notes ...
Page 231: ...GBC StreamPunch Ultra Ultra MP 02 03 2017 Adjustments Repairs 4 151 Notes ...
Page 354: ...General Procedures and Information 11 05 2018 GBC StreamPunch Ultra Ultra MP 6 80 Notes ...
Page 356: ...Wiring Data 05 10 2018 GBC StreamPunch Ultra Ultra MP 7 2 This page intentionally left blank ...
Page 359: ...GBC StreamPunch Ultra Ultra MP 05 10 2018 Wiring Data 7 5 Plug Jack connectors ...
Page 369: ...Installation Instructions 02 03 2017 GBC StreamPunch Ultra Ultra MP 8 10 Notes ...