Page 4 - 11
Installation
F 60 C Operation and Maintenance Manual
© April 2001 General Binding Corporation
c) Connect the wires to the Line Terminal Block
(LTB) as illustrated below.
5
6
re d w ire
b lu e w ire
h o t le g
h o t le g
g ro u n d
W A R N I N G
Follow the correct wiring diagram when
supplying power to the laminator. If
improperly connected, you can be seriously
injured or cause damage to the laminator.
d) Secure the main power strain relief to the
cabinet.
e) Turn the junction box power to the ON
position.
f) Verify line voltage with regards to the type of
power being supplied to the laminator at the line
terminal block.
5
6
h o t le g
( A )
h o t le g
( B )
g ro u n d
( C )
• (A) - (B) = 230 ~ 240 VAC
• (A) - (C) = 115 ~ 120 VAC
• (B) - (C) = 115 ~ 120 VAC
g) Replace the control side cabinet cover.
h) Turn the On/ Off to the ON position by
flipping the handle to the up position and press
reset.
Reset
On/ Off
POWER