Page 4 - 6
© GBC Films Group October 2000
Flowcharts - Electrical
Titan 165/ 110 Technical Service Manual
4.3 No cooling fans
1.
Check power to the fans(230vac)
a.
Disconnect and check the output from the main PCB board at the
terminals labeled FAN (230vac). If voltage is not present then replace the
main PCB board.
b.
If voltage is present then replace the fan.