8. Specifications 

 

 
 

 
 
 
 
 
 
 
 
 

 

IV= Input voltage 
OV= Output voltage 
CP=Continuous Power 
SP=Surge Power 
 

 

                       

 

 

 

 

AC  product(s)  connected  are  rated  at 
more  than  the  rated  continuous  output 
power.overload shutdown has occurred.  
 

 

 

 

 
Use  product  with  a  power  rating  less  than  the  rated 
continuous output power;   

AC  Product  is  rated  less  than  the  rated 
continuous  output  power;  high  staring 
surge has caused overload shutdown. 
 

Product  exceeds  inverter's  surge  capability.  Use  a  product 
with starting surge power within the inverter's capability. 
 

Battery is discharged (alarm is sounding).
 

 

Recharge battery. 

Inverter has overheated due to poor 
ventilation  and  has  caused  over 
temperature shutdown.  

 

Switch inverter OFF and allow to cool for 15 minutes. 
Clear  blocked  fan  or  remove  objects  covering 
unit.Locate unit to a cooler environment.Reduce load 
if continuous operation is required, restart.

 

Input 

voltage 

is 

greater 

than

 

16.0V/31V/61V DC.   

 

Verify  charging  system  is  properly  regulated  and  battery  is 
12V/24V DC nominal.   

 

DC input voltage range 

10.5~15.5V (20~31.0VDC) 

AC output voltage (nominal) 

240VAC 

AC output frequency(Pure sine wave) 

50/60 ±0.5 Hz 

Ambient operating temperature range 

-15 

~ 50 

 

Low battery alarm trigger range (nominal) 

10~10,5VDC (19,5~20VDC) 

Low battery shut down range (nominal) 

9.0~9.5VDC (18~19VDC) 

High battery shut down range (nominal) 

15.5VDC (31VDC) 

Model 

IV 

OV 

CP 

SP 

Fuse 

Dimension (mm) 

Weight (kg) 

34.0133.00

 

12VDC 

220~230VAC 

300W 

600W 

1*30A 

203*107*62 

1.04 

34.0133.10

 

24VDC 

220~230VAC 

300W 

600W 

1*20A 

203*107*62 

1.04 

34.0133.20

 

12VDC 

220~230VAC 

600W 

1200W 

2*30A 

246*107*62 

1.16 

34.0133.30 

24VDC 

220~230VAC 

600W 

1200W 

2*20A 

246*107*62 

1.16 

34.0133.40

 

12VDC 

220~240VAC 

1000W 

2000W 

4*30A 

327*180*95 

3.3 

34.0133.50

 

24VDC 

220~230VC 

1000W 

2000W 

2*30A 

327*180*95 

3.3 

34.0133.60 

12VDC 

220~230VAC 

1500W 

3000W 

6*30A 

405*180*95 

4.22 

34.0133.70 

12VDC 

220~230VAC

 

2000W 

4000W 

8*30A 

405*180*95 

5.1 

Summary of Contents for 34.0133.00

Page 1: ...33 30 24V 600W Cod 34 0133 40 12V 1000W Cod 34 0133 50 24V 1000W Cod 34 0133 60 12V 1500W Cod 34 0133 70 12V 2000W Due to the continuous evolution of the products the characteristics and the design of...

Page 2: ...e power inverter the leader in the field of high frequency inverter design From the 12V 24V DC outlet in your vehicle or boat or directly from a dedicated 12V 24V DC battery the inverter will efficien...

Page 3: ...r s AC outlets The inverter will be damaged even if it is switched off Do not expose the inverter to temperatures exceeding 40 C CAUTION Connect inverter only to batteries with a 12V 24V 48V DC nomina...

Page 4: ...7 Positive terminal connect with the positive side of the battery 8 Negative terminal connect with the negative side of the battery 9 Ground terminal connect to the ground counseling electrical power...

Page 5: ...earance above and on all sides of the unit for proper cooling Safe Do not install inverter in a compartment with non sealed batteries or flammable liquids such as gasoline or explosive vapors Clean an...

Page 6: ...ts are first switched on they initially consume more power than their power rating For loading such as motor rectifier there is a surge current when starting Please note the starting current can t exc...

Page 7: ...ut voltage exceeds 16 2 VDC 12V inverter or 31V DC 24V inverter 8 The cooling fan is designed to operate only when the temperature is higher than 40 C 9 In the event of an overload low battery voltage...

Page 8: ...e small loads but not larger ones Voltage drop across DC cables Reduce the cable and use bolder one PROBLEM Measured inverter output is too low Standard average reading AC voltmeter used to measure ou...

Page 9: ...ation is required restart Input voltage is greater than 16 0V 31V 61V DC Verify charging system is properly regulated and battery is 12V 24V DC nominal DC input voltage range 10 5 15 5V 20 31 0VDC AC...

Page 10: ...but la fin de la vie utile du produit il ne peut pas tre retir par l utilisateur Dans ce cas les centres de r cup ration et de recyclage peuvent suivre le d montage de retirer la batterie ES El produc...

Page 11: ...od 34 0133 30 24V 600W Cod 34 0133 40 12V 1000W Cod 34 0133 50 24V 1000W Cod 34 0133 60 12V 1500W Cod 34 0133 70 12V 2000W A causa della continua evoluzione dei prodotti le caratteristiche ed il diseg...

Page 12: ...V 24V DC del vostro veicolo o imbarcazione o direttamente connesso alla batteria ed in grado di fornire alla sua uscita una tensione alternata in grado di alimentare una vasta gamma di apparecchi funz...

Page 13: ...o da scintille provocate da cattivi collegamenti elettrici Quando si lavora su apparecchiature elettriche assicurarsi sempre della presenza di qualcuno nelle vicinanze pronto ad aiutarvi in caso di em...

Page 14: ...ette un segnale acustico 5 Ventola di raffreddamento In grado di raffreddare l inverter durante il funzionamento 6 Terminale positivo Dove connettere il polo positivo della batteria 7 Terminale negati...

Page 15: ...che sia Secco Non esporlo a contatto diretto con acqua o spruzzi Fresco Meglio se utilizzato in ambienti con temperature comprese tra 0 C e 40 C Tenere lontano da bocchette di riscaldamento forni o al...

Page 16: ...alletto posto sul retro dell inverter In caso di installazione fissa necessaria la connessione a un palo metallico piantato nel terreno fino alla profondit di 1 2m anche il pacco batterie se non dotat...

Page 17: ...rrenti necessarie per l avviamento del motore Non sono progettate per fornire forti correnti per lunghi periodi 8 Se viene collegato un apparecchio che richiede una potenza superiore a quella che pu f...

Page 18: ...eguato filtraggio di alimentazione interna ed facile udire un leggero quando vengono alimentate da un inverter Generalmente l unica soluzione quella di utilizzare prodotti audio con un filtro di quali...

Page 19: ...apparecchio collegato all inverter non funziona LED rosso acceso L apparecchio collegato all inverter ha richiesto una potenza maggiore a quella fornibile dall inverter stesso ed intervenuta la prote...

Page 20: ...las normas locales sobre la recolecci n separada de bater as ya que la eliminaci n correcta ayuda a evitar consecuencias negativas para el medio ambiente y para la salud La bater a est incorporada pa...

Page 21: ...21 GR 2013 56 CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING RISK OF ELECTRIC SHOCK DO NOT OPEN ATTENZIONE RISCHIO DI SCOSSE ELETTRICHE NON APRIRE AVVISO RISCHIO DI SCOSSE NON APRIRE...

Reviews: