            WARNING!

 

Shock hazard. Keep away from children.

 

● The inverter generates the same potentially lethal AC power as a normal household wall outlet. Treat it with the 

same respect that you would any AC outlet. 

● Do not insert foreign objects into the inverter’s AC outlets, fan or vent openings. 
● Do not expose the inverter to water, rain, snow or spray.       
● Do not under any circumstances, connect the inverter to utility power AC distribution wiring. 

            WARNING!

 

Heated surface. 

The  inverter’s  housing  may  become  uncomfortably  warm,  reaching

 

50°C

 

under  extended  high  power 

operation. Ensure at least 5 cm of air space is maintained on all sides of the inverter. During operation, keep 
away from materials that may be affected by high temperatures. 

            WARNING

!   

Explosion hazard. 

            ● Do not use the inverter in the presence of flammable fumes or gases, such as in the bilge of a gasoline powered 

boat  ,  or  near  propane  tanks.  Do  not  use  the  inverter  in  an  enclosure  containing  automotive-type,  lead-acid 
batteries. These batteries , like sealed batteries, vent explosive hydrogen gas, which can be ignited by sparks 
from electrical connections. 

            ● When working on electrical equipment always ensure someone is nearby to help you in an emergency. 
 

            CAUTION! 

            ● Do not connect live AC power to the inverter’s AC outlets. The inverter will be damaged even if it is switched off. 
            ● Do not expose the inverter to temperatures exceeding 40°C 

            CAUTION! 

            ●  Connect  inverter  only  to  batteries  with  a  12V/24V/48V  DC  nominal  output.  Wrong  DC  input  will  not  supply 

enough voltage or damage the inverter. 

 

            CAUTION! 

Do not use the inverter with the following equipment: 

            ●  Small  battery  operated  products  such  as  rechargeable  flashlights,  some  rechargeable  shavers,  and   

night-lights that are plugged directly into an AC receptacle to recharge. 

            ● Certain battery chargers for battery pack used in hand powered tools. These chargers will have warning labels 

stating that dangerous voltages are present at the charger’s battery terminals. 

            ● Connect inverter only to batteries with a 12V/24V DC nominal output. A battery with 6V/12V/24V nominal output 

will not supply enough voltage and a battery with 24V/48V/96V nominal output will damage the inverter. 

 

            CAUTION!

 Any internal adjustment on the inverter is prohibit! 

 

3. Auto protect functions   

These advanced safety features are built into the inverter. Electronic overload protection with automatic shutdown. 

  Built-in internal backup DC fuse provides added safety. 

  Low battery voltage warning followed by automatic shutdown. 

  High input voltage protection with automatic shutdown. 

  Over temperature protection with automatic shutdown. 

  Output short circuit protection. 

4. Product characteristic   

   
Please make sure you have known the basic characteristic of this power inverter before use .   

 
 

Summary of Contents for 34.0133.00

Page 1: ...33 30 24V 600W Cod 34 0133 40 12V 1000W Cod 34 0133 50 24V 1000W Cod 34 0133 60 12V 1500W Cod 34 0133 70 12V 2000W Due to the continuous evolution of the products the characteristics and the design of...

Page 2: ...e power inverter the leader in the field of high frequency inverter design From the 12V 24V DC outlet in your vehicle or boat or directly from a dedicated 12V 24V DC battery the inverter will efficien...

Page 3: ...r s AC outlets The inverter will be damaged even if it is switched off Do not expose the inverter to temperatures exceeding 40 C CAUTION Connect inverter only to batteries with a 12V 24V 48V DC nomina...

Page 4: ...7 Positive terminal connect with the positive side of the battery 8 Negative terminal connect with the negative side of the battery 9 Ground terminal connect to the ground counseling electrical power...

Page 5: ...earance above and on all sides of the unit for proper cooling Safe Do not install inverter in a compartment with non sealed batteries or flammable liquids such as gasoline or explosive vapors Clean an...

Page 6: ...ts are first switched on they initially consume more power than their power rating For loading such as motor rectifier there is a surge current when starting Please note the starting current can t exc...

Page 7: ...ut voltage exceeds 16 2 VDC 12V inverter or 31V DC 24V inverter 8 The cooling fan is designed to operate only when the temperature is higher than 40 C 9 In the event of an overload low battery voltage...

Page 8: ...e small loads but not larger ones Voltage drop across DC cables Reduce the cable and use bolder one PROBLEM Measured inverter output is too low Standard average reading AC voltmeter used to measure ou...

Page 9: ...ation is required restart Input voltage is greater than 16 0V 31V 61V DC Verify charging system is properly regulated and battery is 12V 24V DC nominal DC input voltage range 10 5 15 5V 20 31 0VDC AC...

Page 10: ...but la fin de la vie utile du produit il ne peut pas tre retir par l utilisateur Dans ce cas les centres de r cup ration et de recyclage peuvent suivre le d montage de retirer la batterie ES El produc...

Page 11: ...od 34 0133 30 24V 600W Cod 34 0133 40 12V 1000W Cod 34 0133 50 24V 1000W Cod 34 0133 60 12V 1500W Cod 34 0133 70 12V 2000W A causa della continua evoluzione dei prodotti le caratteristiche ed il diseg...

Page 12: ...V 24V DC del vostro veicolo o imbarcazione o direttamente connesso alla batteria ed in grado di fornire alla sua uscita una tensione alternata in grado di alimentare una vasta gamma di apparecchi funz...

Page 13: ...o da scintille provocate da cattivi collegamenti elettrici Quando si lavora su apparecchiature elettriche assicurarsi sempre della presenza di qualcuno nelle vicinanze pronto ad aiutarvi in caso di em...

Page 14: ...ette un segnale acustico 5 Ventola di raffreddamento In grado di raffreddare l inverter durante il funzionamento 6 Terminale positivo Dove connettere il polo positivo della batteria 7 Terminale negati...

Page 15: ...che sia Secco Non esporlo a contatto diretto con acqua o spruzzi Fresco Meglio se utilizzato in ambienti con temperature comprese tra 0 C e 40 C Tenere lontano da bocchette di riscaldamento forni o al...

Page 16: ...alletto posto sul retro dell inverter In caso di installazione fissa necessaria la connessione a un palo metallico piantato nel terreno fino alla profondit di 1 2m anche il pacco batterie se non dotat...

Page 17: ...rrenti necessarie per l avviamento del motore Non sono progettate per fornire forti correnti per lunghi periodi 8 Se viene collegato un apparecchio che richiede una potenza superiore a quella che pu f...

Page 18: ...eguato filtraggio di alimentazione interna ed facile udire un leggero quando vengono alimentate da un inverter Generalmente l unica soluzione quella di utilizzare prodotti audio con un filtro di quali...

Page 19: ...apparecchio collegato all inverter non funziona LED rosso acceso L apparecchio collegato all inverter ha richiesto una potenza maggiore a quella fornibile dall inverter stesso ed intervenuta la prote...

Page 20: ...las normas locales sobre la recolecci n separada de bater as ya que la eliminaci n correcta ayuda a evitar consecuencias negativas para el medio ambiente y para la salud La bater a est incorporada pa...

Page 21: ...21 GR 2013 56 CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING RISK OF ELECTRIC SHOCK DO NOT OPEN ATTENZIONE RISCHIO DI SCOSSE ELETTRICHE NON APRIRE AVVISO RISCHIO DI SCOSSE NON APRIRE...

Reviews: