T1 CrossConnect Installation & Operation Manual
3 – Installation & Wiring
Version 2
3-12
GatesAir
Intraplex Products
Figure 3-13. Turning On/Off the Bias Jumper Connectors
Figure 3-14 shows a modified network structure using a null modem. This structure is another
alternative to the network structure in Figure 3-11.
Figure 3-14. Alternative Network Structure with a Null Modem
In this network structure using a null modem, the sections using the RS 485 are isolated so the bias
resistor can remain turned on for all the DCS units. However, a null modem cable (not included) is
needed to swap the transmit and receive when running from the RS 232 of a DCS to the RS 232 of
another DCS.
3.4.4
External Contact/Status Port Wiring (Optional)
The external status port on the MA-251A and MA-252A allows you to connect external contact closure
devices and map status/alarm indicators. Table 3-10 lists the pin assignments. Section 3.9.1 –
External Contact/Status Port Inputs
, and Section 3.9.2 –
External Contact/Status Port Outputs
give
more information on using this port.